User`s manual

PC2-CamLink User's Manual Part I: PC2-CamLink Board 61
Error on Pixel Clock: No pixel clock detected from the camera.
Visual indicators on the PCI bracket give a clear indication of the acquisition and trigger status.
Additional LEDs are present at the back of the board, below the floppy power connector. These
LEDs indicate a camera power overflow.
The rest of trigger-to-image reliability is handled internally by the ACU to correctly synchronize
acquisition with camera control and image transfer. This is done automatically and does not require
user application involvement.
The following table summarizes trigger-to-image reliability features on the PC2-CamLink:
Features Descriptions Characteristics Supported by
PC2-CamLink
Acquisition
Deterministic
Camera Control
Trigger input to strobe
output delay
Yes
EXSYNC Alignment
(digital)
Aligned to the first
occurrence of HD after
trigger input.
N/A
Aligned immediately
with trigger input
(instantaneous capture)
Yes
Double pulse integration
control on a single pin
Yes
Strobe alignment control Aligned with the first
FVAL
Yes
(IFC only)
Aligned with the
external trigger
Yes
Camera control timing
granularity
1 microsecond
Maximum delay 64 msec
Maximum duration 64
msec
Yes
1 msec
Maximum delay 65
Seconds
Maximum duration 65
Seconds
Yes
Variable frame length
acquisition control
(linescan)
The ability to acquire
images of varying size.
Utilizes a start and stop
acquisition control
signal.
Yes