User`s manual

Spyder 3 GigE User Manual
03-032-10158-09 DALSA
102
Mnemonic Syntax Parameters
Description
set GPIO input
sgi
i i
Sets the GPIO input signal.
i = input number in a range from 0 to 3
i = signal to use where:
0 = disabled
1 = TTL
2 = LVDS
set GPIO output
sgo
i i
Sets the GPIO output signal.
i = output number in a range from 0 to
3
i = output signal to use where:
0 = disabled
1 = TTL
2 = LVDS
set lower threshold
slt
i
The pixels below the lower threshold
are checked for and reported in the
end-of-line sequence in a range from
0-
4095.
set prnu coeff
spc
x i
Set the PRNU coefficient.
x=pixel number within the range 1 to
sensor pixel count.
i= PRNU value within the range 0 to
28671.
set readout mode
srm
i
Set the readout mode in order to clear
out dark current charge in the vertical
transfer gates before the sensor is read
out.
0 = Auto.
1 = Dark current clear.
2 = Immediate readout. Does not clear
dark current.
set subtract background
ssb
t i
Subtract the input value from the
output signal.
t = Tap value. 0 for all taps or 1 to
number of camera taps for individual tap
selection.
i = Subtracted value in a range from 0
to
4095.
set sync frequency
ssf
i
Set the frame rate to a value from
300Hz to 37000Hz (2k model) or
300Hz to 68000Hz (1k model). Value
rounded up/down as required.
set system gain
ssg
t i
Set the digital gain.
t = tap selection, either 1 to 2, or 0 for
all taps
i = Digital gain in a range from 0 to
65535. The digital video values are
multiplied by this number.