User`s manual
Spyder 3 GigE User Manual
03-032-10158-09 DALSA
104
A5 Error Handling
The following table lists warning and error messages and provides a description and
possible cause. Warning messages are returned when the camera cannot meet the full
value of the request; error messages are returned when the camera is unable to complete
the request.
Table 15: Warning and Error Messages
Message Description
OK> SUCCESS
Warning 01: Outside
of specification>
Parameter accepted was outside of specified operating range (e.g. gain
greater than ±10 dB of factory setting).
Warning 02: Clipped
to min>
Parameter was clipped to the current operating range. Use gcp to see
value used.
Warning 03: Clipped
to max>
Parameter was clipped to the current operating range. Use gcp to see
value used.
Warning 04: Related
parameters
adjusted>
Parameter was clipped to the current operating range. Use gcp to see
value used.
Warning 05: Can’t
set LVDS for this
GPIO signal
Input 3 and Output 3 cannot be set to use an LVDS signal.
Warning 07:
Coefficient may be
inaccurate A/D
clipping has
occurred>
In the region of interest (ROI) greater than 6.251% single or 1% of
averaged pixel values were zero or saturated.
Warning 08: Greater
than 1% of
coefficients have
been clipped>
A FPN/PRNU has been calculated to be greater than the maximum
allowable 511 (8).
Warning 09: Internal
line rate inconsistent
with readout time>
Message Description
Error 02:
Unrecognized
command>
Command is not available in the current access level or it is not a valid
command.
Error 03: Incorrect
number of
parameters>
Error 04: Incorrect
parameter value>
This response returned for
· Alpha received for numeric or vice versa
· Not an element of the set of possible values. E.g., Baud Rate
· Outside the range limit
Error 05: Command
unavailable in this
mode>
Command is valid at this level of access, but not effective. Eg line rate
when in smart EXSYNC mode