User`s manual
Spyder 3 GigE User Manual
03-032-10158-09 DALSA
90
A4.7 Returning Camera Settings
Returning All Camera Settings with the Camera
Parameter Screen
The camera parameter (gcp) screen returns all of the camera’s current settings. The table
below lists all of the gcp screen settings.
To read all current camera settings, use the command:
Syntax:
gcp
GCP Screen Description
GENERAL CAMERA SETTINGS
Camera Model No.: SG-10-02K80-00-R
Camera model number.
Camera Serial No.: xxxxxxxxx
Camera serial number.
Firmware Version: xx-xx-xxxxx-xx
Firmware design
revision number.
CCI Version: xx-xxx-xxxxx-xx
CCI version number.
FPGA Version: xxx.xx
FPGA revision number.
UART Baud Rate: 115200
Serial communication
connection speed set
with the
119Hsbr command.
See
296HSetting Baud Rate
on page
297H55 for details.
Dual Scan Mode: High Sensitivity
Current sensitivity
mode set with the
120Hshm
command. See section
298HA1.1 Sensitivity Mode
for details.
Camera Mode: 2 taps, 12 bits
Current bit depth
setting set with the
sdm
command. Refer to
section
299HA1.3 Setting the
Bit Depth for details.
Readout Mode: Off
Current readout mode
status. Set using the
srm command.
Exposure Mode: 7
Current exposure mode
value set with the
121Hsem
command. See section
300HA1.4 Exposure Mode,
Readout Mode, Line
Rate and Exposure
Time for details.