User`s manual
Spyder 3 GigE User’s Manual
DALSA 03-032-10158-09
91
SYNC Frequency: 5000.00 Hz
Current line rate. Value
is set with the
122Hssf
command. See section
301HA1.4 Exposure Mode,
Readout Mode, Line
Rate and Exposure
Time for details.
Exposure Time: 200.00 uSec
Current exposure time
setting. Value is set
with the
123Hset command.
See section
302HA1.4
Exposure Mode,
Readout Mode, Line
Rate and Exposure
Time for details.
CCD Direction: internal/forward
Current direction
setting set with scd
command. Refer to
section
303HA1.2 CCD Shift
Direction for details.
Horizontal Binning: 1
Current horizontal
binning factor set with
the
sbh command.
Video Mode: video
Current video mode
value set with the
124Hsvm
command. See section
304HA4.1 Generating a Test
Pattern for details.
Region of Interest: (1,1) to (2048, 1)
Region of interest size
set with the
125Hroi
command. See section
305HA2.1 Setting a Region of
Interest (ROI) for
details.
End-Of-Line Sequence: on
States whether an end
of line sequence is
turned on or off. Set
using the
126Hels
command. See section
306HA2.3 End-of-line
Sequence for details.
FFC Coefficient Set: 0
Current pixel coefficient
set loaded. Refer to
section
307HA3.1 Saving and
Restoring PRNU and
FPN Coefficients for
details.
FPN Coefficients: off
States whether FPN
coefficients are on or
off. Set with the
127Hepc
command. Refer to
section
308HA2.2 Analog
and Digital Signal
Processing Chain for
details.