Specification
514
DESIGN WITH CONFIDENCE
daltile.com
EVALUATING THE STATIC COEFFICIENT OF  
FRICTION (COF) OF CERAMIC TILE, ASTM C1028-06
COF* denes the relative slip resistance of oor surfaces. The tile 
industry uses ASTM C1028-06 to measure the COF published in 
Dal-Tile’s product literature. The procedure involves the use of a 
calibrated dynamometer, a specied neolite heel assembly, a standard 
reference tile surface, and a 50 pound weight. This procedure measures 
the maximum force required to initiate motion in the testing assembly 
in four perpendicular directions. The values are recorded and an 
averaging calculation is performed that determines the static COF. 
WATER ABSORPTION, ASTM C373-88 
Water absorption is measured using ASTM C373-88. Individual tiles 
are weighed, saturated with water, then weighed again. The percent 
difference between the two conditions is referred to as the water 
absorption value. Tiles are classied according to water absorption 
percentages as follows:
Impervious  Tiles exhibiting 0.5% or less.
Vitreous   Tiles exhibiting more than 0.5%   
but not more than 3.0%.
Semi-Vitreous   Tiles exhibiting more than 3.0%   
but not more than 7.0%.
Non-Vitreous  Tiles exhibiting more than 7.0%. 
SCRATCH HARDNESS (MOH’S SCALE RATINGS)
The relative hardness of glazed tile is an important issue that should be 
addressed when selecting a tile. The test is performed by scratching 
the surface of the tile with different minerals and subjectively assigning a 
“MOH’s Scale Hardness” number to the glaze, the softest mineral used 
is talc (“1” rating), the hardest is a diamond (“10” rating). Other minerals 
of varying hardness provide Moh’s Scale Hardness values of 5 to 7 are 
suitable for most residential oor applications. A value of 7 or greater 
is normally recommended for commercial applications.
BREAKING STRENGTH CERAMIC TILE, ASTM C648-04
Ceramic tiles used on oors and walls must be able to withstand the 
expected load bearing capacity of various installations. The tile industry 
uses ASTM C648-04 to determine the strength and durability of the 
tile. A force is applied to an unsupported portion of the tile specimen 
until breakage occurs. The ultimate breaking strength is then recorded 
in pounds. Final selection of the tile should be based upon the breaking 
strength and the appropriate installation method. Tile integrity is critically 
dependent upon proper installation. Dal-Tile recommends strict 
adherence to industry installation guidelines set forth in ANSI A108, 
A118 and A136.
CHEMICAL RESISTANCE, ASTM C650-04
Chemical resistance is measured using ASTM C650-04. A tile sample is 
placed in continuous contact with a variety of chemicals for 24 hours, 
rinsing the surface and then examining the surface for visible variation.
PORCELAIN/CERAMIC TEST RESuLTS
INDUSTRY STANDARDS
The American Society for Testing and Materials (ASTM) and the 
American National Standards Institute (ANSI) are nationally recognized 
organizations, which identify and develop industry test methods and 
technical standards.
*Neither ASTM nor ANSI establish an industry standard identifying a 
minimum COF value whereby ceramic tile may be labeled "slip resistant". 
All Standard Grade ceramic tile products manufactured by or for Daltile 
meet or exceed the requirements of ANSI A137.1. See product pages 
for series-specic technical data.
Class Zero
Not recommended for use on oors.
Class One
(Light Residential)
1
Light Traffic - Residential oor coverings in areas 
subject to soft-soled footwear or normal footwear 
trafc, without scratching dirt (i.e. domestic 
bathrooms and bedrooms without exterior access).
Class Two
(Residential)
2
Medium to Light Traffic - Residential oor coverings 
in areas subject to soft-soled footwear or normal 
footwear trafc with small amounts of scratching 
dirt (i.e. rooms in the living areas of homes except 
kitchens, entrances and other areas that may be 
subjected to high usage).
Class Three
(Heavy Residential 
or Light Commercial)
3
Medium to Heavy Traffic - Residential or light 
commercial may withstand normal footwear and 
regular trafc, with some dirt and/or other abrasives 
present in limited quantities. Tile in this class may be 
used in light commercial installations with limited 
foot trafc and with no direct access to the outside. 
Examples may include residential kitchens and 
hallways with limited trafc from the outside.
Class Four
(Commercial)
4
Heavy Traffic - Residential and commercial oor 
coverings subjected to considerable trafc and 
scratching dirt (i.e. entrances, workrooms, inns, 
exhibition halls, and sales rooms, as well as other 
rooms in public and private buildings). Floors should 
be adequately protected against scratching dirt at 
the entrances to buildings by either oor mats or 
some other footwear cleaning device.
Class Five
(Heavy Commercial)
5
Heavy Traffic - Heavy commercial oor coverings 
subject to heavy trafc with very abrasive soil.
ABRASION RESISTANCE, ASTM C1027-99
The durability of glazed tile is measured, subjectively, by observing 
the visible surface abrasion of the tile when subjected to the ASTM C 
1027-99 testing procedure. Dal-Tile evaluates glazed tile recommended 
for oor applications using this test method which includes the following 
classication system: 
SHADE VARIATIONS
Tiles range from complete inconsistency to a more random appearance. 
Here’s an overview of color and shading of individual tile selections.
 Monochromatic (V0) - Very uniform, monochromatic color
 Low (V1) - Consistent color within each tile and from tile to tile
 Medium (V2) - Color variation within each tile
 High (V3) - Some variation from tile to tile, and within each tile
 Random (V4) - Considerable variation from tile to tile