User's Manual
Doc. No.
Rev.
Date
1.00
2011-12-08
Damm Cellular Systems A/S, Denmark
TETRAFLEX
®
V7.5 MANUAL - Network Management
TetraFlex® 7.5
Manual
3-27
*) If the auto convert flag is set, then only freq. which are derivable from Tetra primitives are
allowed (follows Carrier Number).
3.3.4.6.10 Neighbor cells
Configure the neighbor cells as auto (recommended for small systems covering a uniform
area) or manual (recommended for larger systems or small systems covering a line, ex, a
highway or a railway etc.
Right mouse click on the following items allows change of the configurations.
Mode
○ Change between “Auto (All cells)” and “Selected cells only”
N1 to N16
○ Neighbor cell setup for the specific node
The following is information only
Active
○ Activation status of the cell
The drop down Active Radio cells / All nodes changes between display of active nodes only,
or both active and not active nodes
3.3.4.6.11 Voice GW
Right mouse click on the following items allows change of the configurations.
Active
Activation of GW (yes or No)
Org.
Gateway organization number that are allowed
Reg.
Selection if GW should register at the SIP device
or not
Remote IP
IP address of SIP device
Rem. Port
Remote port number. Default 5060
Loc. Port
Local port number. Default 5060