User's Manual

Doc. No.
Rev.
Date
DRAFT
1.01
2012-01-27
Damm Cellular Systems A/S, Denmark
TetraFlex
®
7.5 Manual - SB421 Configuration
TetraFlex® 7.5
Manual
2-59
2.5.1.4.1 Default network card IP address setup
As default the IP addresses are defined as
o LAN Network Card: 172.16.1.10
This IP address must be equal to the IP address defined for the BSC
If these IP’s addresses are miss-configured, in addition to a non working system,
also a PS alarm may show on the BSC LED’s
o WAN Network Card: DHCP
2.5.1.5 MAC address Set-up
On delivery from DAMM, the MAC is set to the correct value
BSC´s delivered from 01.01.2008 has the MAC address stored in a flash device. No action
needed.
BSC´s delivered before 01.01.2008 (MAC address label may be present on the BSC unit)
may have the MAC redefined.
The MAC is stored on the storage device (HD or CF). This means that if the system is cloned
from another SB421 or reinstalled with the image file available at the http://www.damm.dk,
the MAC address MUST be changed from the MAC specified in the source file to the actual
value valid for the specific SB421 serial number.
If MAC cannot be determined, contact support@damm.dk with the serial number in question
To enter / change the MAC, follow the procedure as stated.
o Look up and write down the MAC address noted on the label placed in the upper
right corner of the CPU (BSC) unit in the SB421. See
o Figure 1-2: BSC421
o Use the file explorer and go to C:\Programs\MacMakeUp\MacMakeup.exe
Figure 2-10: Start MacMakeUp Application
o In the MacMakeUp application select the 8255xER PCI Adapter
o Enter the MAC address (Enter value like 000FE3000431)
o Press “Change”
o Close the application
o Re-open MacMakeUp and check that the MAC is actually changed / saved
o Disable and then enable the WAN net card to make MAC change valid.