User's Manual

Doc. No.
Rev.
Date
1.00
2011-12-08
Damm Cellular Systems A/S, Denmark
TETRAFLEX
®
V7.5 MANUAL - Network Management
TetraFlex® 7.5
Manual
3-14
3.3.4 Graphical tools for fast Access and information overview
Figure 3-12: Application select and alarms
The Graphical tool for fast selection has 7 access icons and 5 notifications
NOTE: the Node, Map, and Status windows are linked. This means that pointing to a node in
one of the windows automatically changes the window to show the information’s for chosen
node.
3.3.4.1 Notification Icons
Four information icons are present on the graphical tool bar.
o Nodes* Number of nodes presently active
o Log Servers Number of Log Servers attached to the system
o Registrations Number of registered units on system
o Group calls Numbers of on-going Group calls
o Indv. Calls Numbers of on-going Individual calls
When moving the mouse to the Nodes field the actual status is shown:
o Missing Numbers of nodes with a missing alarm
o Two Active Numbers of nodes where 2 BSC are active at the same time
o No Active Numbers of nodes where no BSC are active
o L3 Blocked Number of level 3 blocking alarms present
o L2 Alarm Number of level 2 non-blocking alarms present
o L1 warning Number of level 1 warnings present
o Ok Number of nodes that are ok, without alarms
If one of or more Alarms are present the Nodes field turn into red and the alarm sound alerts.
A yellow field indicates that one or more warning is/are present.