User's Manual

Doc. No.
Rev.
Date
1.00
2011-12-08
Damm Cellular Systems A/S, Denmark
TETRAFLEX
®
V7.5 MANUAL - Network Management
TetraFlex® 7.5
Manual
3-30
3.3.4.6.13 PD GW
Note: Use of Packet Data GW’s must be set in the Node Dongle.
Right mouse click on the following items allows change of the configurations.
Active - Gateway activated (can be deactivated by right clicking)
Status Right click to acknowledge or unacknowledge alarms
RIPv2 Yes RIPv2 is used No Static routing is used
A drop down box allows the view to shift between All Nodes and Active Cells
For details on the Packet Data configuration please see section 2.12 Packet Data Gateway.
3.3.4.6.14 App GW
Note: Number of application GW’s must be set in the Node Dongle and API dongle must be
present in the client PC. DAMM Dispatcher application uses the application GW and uses
one connection. To run the Dispatcher a Dispatcher dongle must be present in the PC where
the dispatcher is running.
Right mouse click on the following items allows changing the configurations.
Active - Gateway activated (can be deactivated by right clicking)
Max - Max connection count, can be changed by right click on it up to the
max. in the dongle.