To configure the Packet Data gateway use the Network Management program (NM), BSC-
GUI or the TetraOM application (OM)
NOTE: Packet Data GW configuration is only needed for Packet Data access from TetraFlex
to the public world. PD access Tetra to Tetra is always available and need no configuration.
o BSC-GUI:
Right mouse click on the following items allows change of the configurations.
Configured: Yes or No is PD GW active
RIPv2: If Yes RIPv2 is used If No Static routing is used.
Active mobiles count: Numbers of active mobile connections
o TetraOM:
Activate the packet data gateway using S74/CNFG/+.
S74/RIP/+ Activated RIP
o Network Management
These parameters can also be set from NM please see chapter 3 Network Manager
Use the OM command S71/SUBIPADD/”IP address range”/”MASK” to configure
an IP address range defined by the MASK.
Configure the packet data gateway Node using the OM command S21/”Profile
number”/PGNODE/x/”Node Number”. Where x is 1 for primary GW and x is 2 for
alternate GW
The following is information only
o Status
The drop down box “All Nodes / Active GWs changes between display of active nodes
only, or both active and not active nodes