2.13.8 Configuration file
Examples of how to use a txt editor to set the connection configuration of the API DLL in the
config.txt file:
NOTE: All blanks must be filled out. This means that a SSI must be 8 digits, MNC must be 5
digits, and IP address segments must be 3 digits and so on.
;***********************************************
;*** TetraFlex API DLL Configuration ***
;***********************************************
; Date/time: 2008-12-15 10:11:39
;***** Common *****
71/SSI/01000092 Application SSI must be defined in subscriber reg.
71/MNC/16029 MNC Mobile Network Code (Same as in NM)
71/MCC/0238 MCC Mobile Country Code (Same as in NM)
71/PIN/12345 PIN: If use must also be defined in subscriber reg.
71/OMPORT/42382 Access port for TetraOM (cannot use 42380)
;***** Gateways *****
72/0/010.239.028.003/BUK1 Range of node IP addresses where the API can
72/1/010.239.016.200/TetraStar connect.
72/2/- The API will try to connect to first IP, if not present
72/3/- then the next will be tried and so on
72/4/-
72/5/-
72/6/-
72/7/-
72/8/-
72/9/-