User's Manual

Doc. No.
Rev.
Date
DRAFT
1.01
2012-01-27
Damm Cellular Systems A/S, Denmark
TetraFlex
®
7.5 Manual - TetraOM
TetraFlex® 7.5
Manual
2-145
63 Internal GPS status
63/VER GPS module version
71 Common system configuration
71/TXREFLWR/c SWR alarm setting
98 Hardware ID
99/RESTART Restart BS421 (Soft restart)
*) Alarm BS 421 (OM command 03/A)
Comment
00: TX PLL unlocked
Blocking Alarm (Hardware fault)
01: TX loop unstable
Blocking Alarm (Hardware fault)
03: TX temperature high
Blocking Alarm (TR421 temperature over 80˚C TX stopped)
06: TX output power
Blocking Alarm (Check TX out power)
07: TX ant. reflected L2
Blocking Alarm (can be changed to non blocking with command
71/TXREFLWAR/+)
08: TX ant. reflected L1
Non Blocking Alarm
10: RX PLL unlocked
Blocking Alarm (Hardware fault)
11: RX LO1 injection low
Non Blocking Alarm (Hardware fault)
16: 36.864MHz PLL unlocked
Blocking Alarm (Hardware fault)
18: L3 Frequency Setup
Non Blocking Alarm
19: DSP watchdog
Blocking Alarm
20: DSP Time Sync
Non Blocking Alarm
21: BSC Message Link
Blocking Alarm (No Link to BSC)
22: BSC1 Message Link
Non Blocking Alarm (No Link to BSC1)
23: BSC2 Message Link
Non Blocking Alarm (No Link to BSC2)
24: Time Sync
Non Blocking Alarm
25: Internal GPS RX
Non Blocking Alarm
26: External 1 Sync input
Non Blocking Alarm
27: External 2 Sync input
Non Blocking Alarm
28: Sync Phase Detector
Non Blocking Alarm
29: Century Second error
Non Blocking Alarm