7.5 Manual - TetraOM
TetraFlex® 7.5
Manual
2-146
TR412 (Transciever):
00 SW Versions
02 TR operating mode
03/A Alarm Flags*
05 Display Config/ Status from BSC (BS)
10 TX key state
11 TX output
13 Power setting
21 RSSI level
31 OCXO sync
34 CMoIP downlink status
R/34 CMoIP downlink status Dynamic
98 Hardware ID
*) Alarm TR 412 (OM command 03/A)
Comment
00: TX PLL unlocked
Blocking Alarm (Hardware fault)
01: TX VSWR protection
Blocking Alarm (Hardware fault)
03: TX temperature high
Blocking Alarm (TR412 temperature over 80˚C TX stopped)
04: TX volt. reference
05: TX +26V supply
06: TX output power
Blocking Alarm (Check TX out power)
07: TX ant. reflected L2
Blocking Alarm
08: TX ant. reflected L1
Non Blocking Alarm
09: TX combiner TP high
10: RX PLL unlocked
Blocking Alarm (Hardware fault)
11: RX LO1 injection low
Non Blocking Alarm (Hardware fault)
12: RX LO2 injection low
13: RX TMA/RMA L2
14: RX TMA/RMA L1