and Longitude fields. Set to No the Latitude and Longitude settings can be set manual. OM
command M71/POS/GPS/+ for Yes” and M71/POS/GPS/- for No
Latitude and Longitude: Manual setting of the Latitude and Longitude coordinates of the
Node, This will be overwritten with the actual GPS position if Position change from GPS
allowed is set to Yes. OM command H71/POS/54:54:55:54N/009:48:23:69E
All settings are saved immediately in the configuration file CnfgMain.txt when pressing the Ok
button in the different settings and when executing the OM commands.
The rest of the fields on the Main tab are for information only and cannot be changed from
the BSC-GUI.
Next step is to set the BSS settings- Select the BSS tab:
Most important is to set the Node no. This must be set to chosen node number. This
example shows Node 5. OM command S71/NODENO/005
The remaining parameters can be set from NM too.