User's Manual

Doc. No.
Rev.
Date
DRAFT
1.01
2012-01-27
Damm Cellular Systems A/S, Denmark
TetraFlex
®
7.5 Manual - BS41x Configuration
TetraFlex® 7.5
Manual
2-77
2.7 BS41X CONFIGURATION
2.7.1 Turn on Base Station power
Turn on the BS Power by turning on the switches on the front of the PS411 Power Supplies
and the Mains outlet.
Power-up will take 2-3 minutes, mainly determined by the start-up time of Windows operating
system on the BSC. After Windows re-boot and BSC start-up, all TR41x will re-boot, and the
BSC red alarm LED turns off and the green Active LED turns on.
If a TR41x is not configured in the BSC, the yellow Power LED on the TR41x will proceed to
flash.
During power-up the Power LED of the PS411 Power Supplies will flash until they receives
configuration from the BSC.
2.7.2 Special precautions
NOTE: Batch commands (B/….) are not supported on TR411 and TR412 using the HDLC
bus
2.7.3 Set-up of IP address
The IP address and net-mask shall be set-up in BSC412 Windows settings as the first
configuration step. This is done either with:
o Connect a monitor and USB keyboard / mouse directly to the BSC or
o Connect your PC to the BSC via an Ethernet cable (crossed or straight rough) or
o Start-up Remote Desktop and connect to the IP address of the WAN Ethernet port
And then:
o Configure IP number, net-mask etc. to the required configuration for the LAN and
WAN
Default factory settings (can be ordered to specific settings):
BSC1 LAN: 172.16.1*.10
BSC2 LAN (red.): 172.16.1*.19
BSC1 WAN: DHCP
BSC2 WAN: DHCP
* 1 for single node, or node1 in multinode. This will be 2 for node2 etc.