Setup Guide

Doc. No.
Rev.
Date
1.11 2020-03-06
Damm Cellular Systems A/S, Denmark
BS422 Installation and Setup guideline
BS422
Installation guide-
Specifications subject to change without notice
16
2.1.2 Setting the frequenzies of the BS422
Some useful TetraOM Commands
For detailed OM overview please see OM help files.
Note Only main commands are listed, subcommands may be available
Node Controller:
(Network connection in OM BSC LAN IP and port 1024)
S00 SW Version
S00/C Compiler options
S04 License dongle setting Node
S10 Network status
S12 Tetra Cell Status
S13 Voice GW status
S14 Packet Data Status
S15 Application GW status
S16 Terminal GW status
S20 Subscriber registers
S20/SAVE Save actual register to text file
S20/READ Load data from text file
S21 Subscriber profile
S22 SSI Register Status
R/S65 (repeating) Multicast / Unicast addresses
S71 General Node configuration
R/S99/TS (repeating) Shows all timeslots
TR422 Transceiver:
(Network connection in OM BSC LAN IP and port 42022)
00 SW Version
01 Display TR Status
03/A Alarm Flags*
05 BSC status
06 Input Power
10 TX key state
11 TX output
21 RSSI level
31 OCXO sync
R/34 (repeating) Display all CMoIP connections
R/63 (repeating) Internal GPS status
63/VER GPS module version
71 Common system configuration
71/TXREFLWR/c SWR alarm setting (- Tx reflected blocking alarm (default, +
warning only alarm)
98 Hardware ID
99/RESTART Restart BS421 (Soft restart)