User guide

Dugan Model E-3 User Guide
44
Clock Source
Click the clock source button to select a word clock source. The default is Automatic,
which selects the first valid source from the menu below.
Figure 5-12 Clock source menu
The Model E-3 can perform sample rate conversion on input signals with sample
rates in the range 32–96 kHz. For inputs other than 48 kHz, set the clock source to
Internal. The Dugan’s output is always 48 kHz.
System
When multiple Dugan units are linked, groups a, b, and c span linked units and op-
erate as independent automatic mixers.
It is possible to have multiple systems of linked units on your network. These units
will all appear in the top pane. The Model E-3 allows 16 systems in a network.
In the rare instance that requires multiple systems:
1. Select the first unit to include in the system by clicking it in the top pane.
2. Click the system button and select a unique number for that system.
3. Repeat for each unit in that physically linked system, making sure to use the same
number for each unit in the system.
4. Repeat steps 1–3 for each system.