21. Conguring the Danalock V3 with click-commands
You can congure the Danalock via the button found in the
small hole on the top of the lock. When you click through
settings, the LED will change color according to the following
scheme. When you get to the setting you want to change
wait for 5 seconds and the Danalock will react to your
command. This gives you plenty of time to navigate to the
right command. If you make a wrong number of clicks, just
stop at a number of clicks where the LED doesn’t light up
and wait for 5 seconds. The LED will ash red to indicate
that it has timed out.
Clicks
Color Activity
2 Yellow Manual calibration
Start by turning the Danalock to the desired unlocked position. Start the
calibration with the click command and wait for the LED to start blinking
yellow. Turn the Danalock to the desired locked position while the LED blinks
and click the button once to save the locked position. The Danalock will
conrm with a green blink. If the lock doesn’t receive a response from you
within 30 seconds the calibration will be canceled.
3 White Auto calibration
Start by turning the Danalock to unlocked position and lifting the handle if
needed. The door has to be left open while the Danalock auto calibrates.
Start the auto calibration with the click command. The Danalock will blink
white while auto calibrating.