Install Instructions

Instructions 013G8070
RA to RA 2000 Operator Adapter
VIUHA122 © Danfoss 06/07
The older Danfoss RA valve is distinguished by the large silver threaded nut that connects
the operator to the valve.
There are two versions of RA operators:
a) Operator mounts directly on valve with remote bulb/sensor (not shown)
b) Separate remote mounted operator and remote bulb/sensor (shown at left)
RA to RA 2000:
Installation:
1) Remove the existing RA operator (RA-33 shown) from the valve by turning nut counter
clockwise. Although the valve should backseat, for safety, the system should be off.
2) Remove any existing gasket material from the face of the threads.
3) Assemble the adapter to the valve as shown in the diagram. The gasket should be
placed between the valve and the adapter. Tighten the nut sufciently to prevent leakage.
Valve Mounted Operators:
013G8252
Align the base of the RA2000 operator with the notches on the adapter. Press rmly until
an audible “click” is heard.
013G2922
For tamper resistant operators the Allen screw on the operator must be tightened to secure
to the valve.
In order to use current RA 2000 operators on existing systems with Danfoss RA valves, the adapter
013G8070 must be installed to allow the new operator to t onto the valve.
Crossover Replacement Operator Guide, RA to RA2000
013-7001 RA-6
013-7101 RA-6
=
013G8070
+
Built-in dial and sensor
013G8252
Tamper resistant Built-in with
remote sensor 013G2922
013-7002 RA-33
013-7003 RA-36
013-7004 RA-66
=
013G8070
+
013G8564