User Guide

RI.5G.F2.22 08-1999
Identification Main data
Max. media / ambient temperature: 175 °F (80 °C)
Min. media / ambient temperature: 40 °F (40 °C)
Refrigerants:
NH
3
, HFC, HCFC, CFC
The sensor is non-adjustable!
Mounting
Hot gas pipe
Max. pressure
When used on a hot gas pipe use a distance sleeve to
reduce temperature influence.
A hot gas temperature higher than 210 °F (100 °C), a 2 in.
(5 cm) sleeve is to be used.
Range SWP / MWP Test pressure
0 - 200 psig 400 psig 800 psig
0 - 500 psig 800 psig 800 psig
Electrical connection
© Danfoss A/S (AC-RCMP,jp)
Screen: Isolated from housing
Red: + supply
White: – supply / common
Green: + output signal
Type Symbol Connection Power sypply Output signal
Max.
30 V d.c.
1 - 6 V d.c.
R > 10 k
AKS 32
MADE IN DENMARK
3031
PRESSURE
TRANSMITTER
Type AKS 32 060G2033
Range Pe
PB/MWP
SUPPLY
OUTPUT
+ SUPPLY
- COMMON
OUTPUT
:
:
:
:
:
:
:
0 -> 500 psig
800 psig
9 - 30 V d.c.
1 - 6 V
RED
WHITE
GREEN
00558111
Part number
Identification code
Pressure connection
1
/8 NPT
= 1
1
/16 in.
INSTRUCTIONS
AKS 32
060G2029 and 060G2033
060R9510
060R9510