Product Overview

Data Sheet RX-C Roof Clips
© Copyright 2016 Danfoss VDLWA222 . 04/16 TEL: 866-676-8062, FAX: 416-352-5981 1
General
Information
The Danfoss RX-C Roof Clips are suitable for use with
the RX-C Self Regulating Cables. The clips are de-
signed to secure the cables to asphalt shingles, metal
seam roofs, and gutters.
Materials Required:
RX-C Roof Clip Glue (or other recommended
adhesive)
pliers
caulking gun
Recommended Adhesives:
See roong supply distributors for recommendations.
Ordering Information
Part No. Description Qty
088L3001 RX-C Roof Clips
50 per bag
Part No. Description Qty
Roof Clip Glue RX-C Roof Clip Adhesive
10.3 . oz.
cartridge
Instructions
1. Apply Adhesive:
Apply 0.2 oz. of adhesive to back of clip.
(Please note required application
temperatures when applying glue.)
2. Press Clip to Roof Surface:
Lift shingle & orient clip.
Press down (ensure adhesive ows
through holes).
Do not trim back adhesive beads.
Press shingle down.
3. Install Cables/Close Clamps
Allow proper cure time (typically 24
hours- refer to adhesive.)
Install RX-C de-icing cable.
Use pliers to close clamps (ensuring not
to damage cable).