BRINGING WARMTH TO LIFE Electric Floor Heating PG. 1 Electric Snow Melting PG. 9 Roof & Gutter De-Icing PG. 21 Pipe Freeze Protection PG. 25 Thermal Storage PG.
A Brief History of... October 2006 Danfoss named “Innovation Award Finalist” for LX Floor Heating System. October 2005 Introduces GX Electric Snow Melting product line. Summer 2007 Danfoss upgrades LX Floor Heating Mat to a new “Dual Adhesive” Mat. Spring 2007 Danfoss introduces TX Thermal Storage/Floor Heating product line. Spring 2006 Introduces PX Pipe Trace and RX Roof & Gutter product lines. Summer 2008 Danfoss initiates the U.S. “Go Green” initiative.
Contents: LX ELECTRIC FLOOR HEATING LX Mats LX Cables LX Thermostats LX Accessories Reflect 1 3 5 6 7 GX ELECTRIC SNOW MELTING GX Mats GX Cables GX Controls GX Accessories 9 9 17 20 RX ROOF & GUTTER DE-ICING RX Kits (Residential) RX-C Cable (Commercial) RX Controls RX Accessories 21 22 23 24 PX PIPE FREEZE PROTECTION PX Self Regulating Cable PX Controls PX Accessories Ice Guard Self Regulating Cable 25 28 28 29 TX THERMAL STORAGE & FLOOR HEATING TX-FH Floor Heating TX-SH Thermal Storage TX Controls T
Danfoss LX Electric Floor Heating Dual Self-Adhesive Mats Danfoss LX Electric Floor Heating System (Self-Adhesive Mat & Thermostat) is an affordable luxury that brings warmth to life . It’s a proven technology that is safe, reliable and energy efficient.
Danfoss LX Electric Floor Heating Typical Applications Ordering Information Part No. LX Mats 120V 240V Length (feet) 088L3150 088L3151 088L3152 088L3153 088L3154 088L3155 088L3156 088L3158 088L3160 - 088L3175 088L3176 088L3177 088L3178 088L3179 088L3180 088L3181 088L3182 088L3183 088L3184 088L3185 5.0 7.5 10.0 12.5 15.0 17.5 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 72.5 Please fax/email orders to: 416-352-5981/Custservlx@danfoss.com 120V, 240V Coverage (sq.ft.
Danfoss LX Electric Floor Heating Electric Floor Heating Cables Danfoss LX Electric Floor Heating Cable Systems combine the highest comfort levels with the maximum energy efficiency.
Danfoss LX Electric Floor Heating Electric Floor Heating Cables Ordering Information Part No. 088L3140 088L3141 088L3142 088L3143 088L3144 088L3145 088L3146 088L3147 088L3148 LX Cables Approximate Heat Coverage (sq.ft.) Length (feet) 2” spacing Standard 3” spacing 4” spacing 40 60 80 120 160 200 240 280 315 5 10 15 20 25 35 40 45 50 10 15 20 30 40 50 60 70 80 15 20 25 40 55 65 80 95 105 Ordering Information Part No.
Danfoss LX Electric Floor Heating Electric Floor Heating Thermostats The Danfoss LX Thermostat raises the bar for aesthetic appeal while offering industry-leading functionality.
Danfoss LX Electric Floor Heating LX Power Module The LX Series Power Module makes it easy to connect more heating mats or cables to the same thermostat without the need for contactor panels.
Danfoss Reflect Electric Floor Heating Reflect Insulation Plates Reflect Insulation Plates are a revolutionary designed product that eliminates the need for a top coat on floating floors. When combined with Danfoss LX Heating Cables, Reflect provides the perfect solution for quick and easy installation of electric floor heating under engineered wood or laminate floors. The combination of an insulating sub floor and a heat conducting surface ensures optimum heat is delivered up through the floor.
Danfoss Reflect Electric Floor Heating Typical Selection Chart Ordering Information LX Cable & Reflect Coverage (sq.ft.
Danfoss GX Electric Snow Melting Electric Snow Melting Mats & Cables Installing a Danfoss GX Snow Melting System provides a permanent solution to the problems caused by cold weather. The GX Snow Melting System is an on demand system that will provide you with improved safety by providing instantaneous relief from snow build up and ice forming. There is no need for costly snow melting chemicals that can damage interior and exterior flooring finishes.
Danfoss GX Electric Snow Melting Typical Applications CONCRETE Concrete slab STONEWORK Pavers Wire mesh Sand Insulation (Optional) Insulation (Optional) Danfoss GX Snow Melting mats & cables Well-drained base Well-drained base Danfoss GX Snow Melting mats & cables ASPHALT* *Notes: Sand Asphalt Insulation (Optional) Danfoss GX Snow Melting mats & cables Please fax/email orders to: 416-352-5981/Custservlx@danfoss.com www.LX.Danfoss.com • Cables can be embedded in sand or concrete (1.0” /25.
Danfoss GX Electric Snow Melting Electric Snow Melting Mats Ordering Information Part No. 088L3222 088L3223 088L3224 088L3225 088L3226 088L3227 088L3228 088L3229 088L3230 088L3231 088L3232 088L3233 088L3234 GX Mats Length (feet) 6.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 30.0 35.0 40.0 45.0 50.0 Ordering Information Part No. 088L3201 088L3202 088L3203 088L3204 088L3205 088L3206 088L3207 088L3208 088L3209 088L3210 088L3211 088L3212 088L3213 088L3214 088L3215 Coverage (sq.ft.
Danfoss GX Electric Snow Melting Electric Snow Melting Mats Ordering Information Part No. 088L3300 088L3301 088L3302 088L3303 088L3304 Length (feet) 16.5 20.0 45.0 60.0 77.5 Ordering Information Part No. 088L3250 088L3251 088L3252 088L3253 088L3254 088L3255 088L3256 088L3257 088L3258 088L3259 088L3260 Length (feet) 15.0 17.5 20.0 22.5 25.0 30.0 35.0 40.0 45.0 52.5 57.5 240V (37W/sq.ft) GX Mats Coverage (sq.ft.) 35 40 90 120 155 Watts (37W/sq.ft.) 1235 1480 3495 4505 5715 GX Mats Coverage (sq.ft.
Danfoss GX Electric Snow Melting Electric Snow Melting Mats Ordering Information Part No. 088L3270 088L3271 088L3272 088L3273 088L3274 088L3275 088L3276 088L3277 088L3278 088L3279 088L3280 088L3281 GX Mats Length (feet) 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 60.0 70.0 80.0 Ordering Information Part No. 088L3290 088L3291 088L3292 088L3293 088L3294 088L3295 088L3296 088L3297 088L3298 088L3299 Coverage (sq.ft.) 20 30 40 50 60 70 80 90 100 120 140 160 480V Watts (50W/sq.ft.
Danfoss GX Electric Snow Melting Electric Snow Melting Cables Ordering Information Part No. 088L3120 088L3121 088L3122 088L3123 088L3124 088L3125 088L3126 088L3127 088L3128 088L3129 088L3130 088L3131 088L3132 088L3133 088L3134 088L3135 Length (feet) 35 50 70 85 105 125 145 160 180 210 245 280 320 355 410 460 Ordering Information Part No.
Danfoss GX Electric Snow Melting Electric Snow Melting Cables Ordering Information Part No. 088L3060 088L3061 088L3062 088L3063 088L3064 088L3065 088L3066 088L3067 088L3068 088L3069 088L3070 088L3071 088L3072 088L3073 088L3074 Length (feet) 50 70 95 115 140 170 190 215 240 285 330 375 425 475 545 GX Cables 277V Approximate Heat Coverage (sq.ft.) Standard 3” Spacing 4” Spacing 10 15 20 25 35 40 45 50 55 65 80 90 100 115 130 15 25 30 40 50 60 65 75 80 95 115 125 145 160 185 Watts (12W/ft.
Danfoss GX Electric Snow Melting Electric Snow Melting Cables Ordering Information Part No. 088L3640 088L3644 088L3646 088L3648 088L3650 088L3652 088L3654 Length (feet) 80 200 330 490 735 820 940 Ordering Information Part No. 088L3620 088L3621 088L3622 088L3623 088L3624 088L3625 088L3626 088L3627 088L3628 088L3629 Length (feet) 100 150 250 300 360 415 465 515 615 714 GX Cables 480V Approximate Heat Coverage (sq.ft.
Danfoss GX Electric Snow Melting Electric Snow Melt Controllers GX 850 ACP Part # 088L3411 Ground Sensors Part # 088L3051 GX 850 Dual Zone Automatic Control Panel The AWARD WINNING Danfoss GX Dual Zone Automatic Control Panel (ACP) is the most optimal solution for keeping any area free of ice and snow.
Danfoss GX Electric Snow Melting Electric Snow Melt Controllers DS-2B/DS-5 Snow Melt Controllers The DS-2B/DS-5 Snow Melt Controllers are designed for pavement snow melt applications. They can be used as a stand alone controller or as a sensor for larger control systems.
Danfoss GX Electric Snow Melting Electric Snow Melting Panels Contactor & Timer Panels The Danfoss Contactor and Timer panels are primarily designed for snow and ice melting applications. All panels are pre-wired and UL listed complete with a NEMA 1 enclosure, wiring diagram, terminal connection block, timer (timer panels), and two or four 3-pole contactors. Timer panels can be used stand alone or in conjunction with an automatic controller.
Danfoss GX Electric Snow Melting GX Timer / Contactor Panels Ordering Information Part No.
Danfoss RX Roof & Gutter De-Icing Roof and Gutter De-Icing Cables Danfoss RX Cables provide the protection needed to prevent ice dams and build-up from damaging RESIDENTIAL buildings, roofs, and gutters. Danfoss RX constant watt heating cables ensure maximum energy efficiency and are designed for use with metal or asphalt roofing. Durable and high-quality materials provide excellent moisture, corrosion and impact protection.
Danfoss RX Roof & Gutter De-Icing Roof & Gutter De-Icing Cables Product Selector for a Basic Roof 1. Total length (ft) of roof line (A) X 5 = RL 2. Total length (ft) of all down spouts (E) X 2 = DS 3.
Danfoss RX Roof & Gutter De-Icing Roof & Gutter De-Icing Controls DS-8 Snow Melt Controller The DS-8 is designed for roof and gutter, snow and ice melting applications. The sealed, low voltage, remote mount precipitation sensor can be mounted in a down spout, on the back of a gutter, under the drip edge, up to 10 feet away, while keeping the main controller in a more convenient and protected location.
Danfoss RX Roof & Gutter De-Icing Roof & Gutter De-Icing Accessories Ordering Information RX Accessories Part No.
Danfoss PX Self-Regulating Cables Pipe Freeze Protection The Danfoss PX Series of SELF-REGULATING Parallel Circuit Heating Cables provide the solution to basic FREEZE PROTECTION applications. The self regulating Danfoss PX series ensures maximum energy efficiency by producing heat only when and where it is needed as it adjusts the power output to the varying conditions along the length of the pipe.
Danfoss PX Self-Regulating Cables Pipe Freeze Protection Ordering Information PX Cables by the Spool Part No. Voltage 088L1402 088L1470 088L1412 088L1471 088L1422 088L1472 088L1432 088L1473 088L1516 088L1517 088L1518 088L1520 088L1519 088L1521 088L1522 088L1523 120V 120V 240V 240V 120V 120V 240V 240V 120V 120V 240V 120V 240V 120V 240V 240V Ordering Information Part No.
Danfoss PX Self-Regulating Cables Pipe Freeze Protection PX Cable Selection Chart Insulation Thickness Pipe Material Pipe Diameter (Inches) 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 6 8 120V 1/2” Min. Metal PVC 3W/ft 3W/ft 5W/ft 5W/ft 5W/ft 5W/ft 8W/ft 8W/ft 10W/ft 10W/ft* - 5W/ft 5W/ft 5W/ft 8W/ft 8W/ft 8W/ft 10W/ft 10W/ft 10W/ft* 10W/ft* - 1” Min. 2” Min.
Danfoss PX Self-Regulating Cables Pipe Freeze Protection Maximum Total Cable Length ft (m) Start-up Temp.
Danfoss Ice Guard Self-Regulating Cables Freeze Protection The Danfoss Ice Guard (SRIG) heating cable provides an easy to use solution for a variety of pipe freeze and roof and gutter applications. The heat output of the conductive core material increases and decreases when it is needed as it adjusts the power output to the varying conditions along the length of the pipe. This ensures maximum energy efficiency by producing heat only when and where it is needed.
Danfoss TXFH Electric Floor Heating Electric Floor Heating Cables Danfoss TXFH Cables are a thick floor heating solution. Thick cables have a larger diameter than the Danfoss LX Floor heating cables, allowing them to be lower in COST, higher in HEAT OUTPUT and more DURABLE. They are installed in mud beds below the flooring materials and are most often used in new construction where overall material cost is a primary concern.
Danfoss TXSH Thermal Storage Heating Thermal Storage Heating Mats & Cables Danfoss TXSH (Storage Heating System) heating mats and cables are energized to warm a thermal mass below the floor surface. Danfoss TXSH is the ideal way to take advantage of local on-peak and off-peak energy prices. When the power system is in off-peak times, energy rates are lower. When on peak times resume, the Danfoss TXSH system shuts off and the heat stored in the floor gently emanates across the floor surface for hours.
Danfoss TX Thermal Storage Heating TX Controls Ordering Information Part No. 088L5130 088L5132 088L5133 TXFH Controls 120V - 240V Description Programmable Thermostat with Floor Sensor Programmable Thermostat with Air Sensor (and floor temperature limiter) Non-Programmable Thermostat with Floor Sensor Floor sensing thermostats include a Floor Sensor with a 10 foot lead For more information see page 5 Ordering Information Part No.
Danfoss TX Thermal Storage Heating Thermal Storage Heating Mats & Cables Typical Applications SAND BED INSTALLATION Wall Insulation Control box including thermostat & contactor Heating cable power lead conduit Min. 2” insulation, 4 feet deep around perimeter Concrete slab Optional vapor barrier Optional insulation Sand bed Conduit with floor sensor (3-6” from cable, min. 2 “ of sand above & below) Heating cables or mats approx.
Technical Information Common Conversion Factors Multiply By To Convert 3,412 3,412 3.281 39.37 0.0929 10.76 2.54 25.4 Kilowatt/hours (kWh) Kilowatt (kW) Meter (m) Meter (m) Square feet (ft2) Square meters (m2) Inches (in.) Inches (in.) To Obtain Cable spacing (inch) = British ther. units/hr (Btuh) British thermal units (Btu) Feet (ft) Inches (in.) Square meters (m2) Square feet (ft 2 ) Centimeters (cm) Millimeters (mm) Area (sq.ft.) x 12 Cable length (ft) o o Fahrenheit to Celsius oF=1.
SUMMARY CONDITIONS FOR SALE AND WARRANTY The acceptance of the order confirmation by the purchaser includes the acceptance of our “General Conditions of Sale and Warranty” as the only ruling condition. No modification of these conditions will be recognized by Danfoss. Any express or implied condition, statement or warranty, statutory or otherwise - not stated herein is excluded. 1.
GENERAL CONDITIONS FOR SALE AND WARRANTY Minimum Order: Handling charges of $25 will be added to all orders less than $100 net. Freight: All prices are FOB point of shipment. Lowest cost transportation allowed on orders of $1500 net or more Partial shipment less then $1500 net will not be freight allowed. Payment Terms: Net 30 days. All orders subject to credit approval. Interest rate of 1% per month applies to late payment.
GO GREEN WITH DANFOSS PART OF THE SOLUTION International cooperation is key to reducing CO2 emissions, an effective response to the global climate challenge also depends on innovation and intelligent technologies that both conserve natural resources and save money. The task before us is to take these proven, energyefficient technologies and apply them to solutions that can immediately reduce CO2 emissions and save energy.