Submittal Sheet

Data Sheet LX Cable
Electric Floor Heating
© Copyright 2013 Danfoss NA.EFH.LXCD.06/13 TEL: 866-676-8062, FAX: 905-285-2055 1
General
Information
Technical Data
Cable Construction: Twin conductor
Rated Voltage: 120V, 240V
Output: 3W/ft. (10W/m)
Heating Element Size: 40 ft. (12.2m) to 630 ft. (192m)
Cold Lead: 10 ft. (3.0 m)
Bending Radius: Minimum 3/4 inch (19 mm)
Cable Diameter: 3/16 inch (4.8 mm)
Conductor Insulation: Te on
TM
FEP
Outer Insulation: PVC
Max. Temperature: 212°F (100°C)
Min. Installation Temp: 50°F (10°C)
See power lead label for NEC connection color code.
The Danfoss LX Electric Floor Heating Cable Systems
combine the highest comfort levels with maximum
energy e ciency. It’s a proven technology thats
safe, reliable and energy e cient.
• Single point connection
Twin conductor cable
• Eliminates EMF’s (Electromagnetic  elds)
• Safety approved for wet locations
The only cable to pass the rigorous
IEEE impact test
• Flexible installation
• Durable construction
• Genuine ten year non-prorated warranty
Part No.
Length
(feet)
Approximate Heat Coverage
Amps
Watts
(3W/ft.)
Ohms
2” spacing
Standard
3” spacing
4” spacing
088L3140 40 5 10 15 1.0 120 120.0
088L3141 60 10 15 20 1.5 180 80.0
088L3142 80 15 20 25 2.0 240 60.0
088L3143 120 20 30 40 3.0 360 40.0
088L3144 160 25 40 55 4.0 480 30.0
088L3145 200 35 50 65 5.0 600 24.0
088L3146 240 40 60 80 6.3 750 19.2
088L3147 280 45 70 95 7.2 860 16.7
088L3148 315 50 80 105 8.0 960 15.0