Specifications

87
VMBMA602
DHP-A 6 8 10 12
R404A R404A R404A R404A
0,95 1,45 1,50 1,60
3,4 3,4 3,4 3,4
3,10 3,10 3,10 3,10
400 400 400 400
2,0 2,3 3,6 4,4
0,4 0,6 0,6 0,6
3/6/9/12/15 3/6/9/12/15 3/6/9/12/15 3/6/9/12/15
14 25 29 32
10
3
/16
4
/20
5
/20
6
/
25
7
/25
14
/30
15
16
3
/16
4
/20
5
/20
6
/
25
7
/25
14
/30
15
16
3
/16
4
/20
5
/20
6
/
25
7
/30
14
/35
15
16
3
/20
4
/25
5
/25
6
/
25
7
/30
14
/35
15
230 230 230 230
3,3 4,2 5,4 5,7
0,4 0,6 0,6 0,6
1,5/3,0/4,5 1,5/3,0/4,5 1,5/3,0/4,5 1,5/3,0/4,5
58 76 97 108
25
3
/32
4
/40
5
25
3
/32
4
/40
5
32
3
/40
4
/50
5
32
3
/40
4
/50
5
5,00 7,02 8,20 9,84
2,85 3,10 2,85 3,00
5,90 7,96 9,85 11,3
3,26 3,45 3,29 3,35
1,8 2,3 3,0 3,4
0,32 0,49 0,58 0,64
0,14 0,22 0,22 0,28
46 83 69 95
46 43 42 52
-20 -20 -20 -20
20/-25 20/-25 20/-25 20/-25
55/20 55/20 55/20 55/20
0,08 0,08 0,08 0,08
2,65/2,85 2,65/2,85 2,65/2,85 2,65/2,85
3,10 3,10 3,10 3,10
180 180 180 180
1,3 2,2 2,7 2,7
1,0 1,3 1,3 1,6
2 2 2 2
690x596x1845 690x596x1845 690x596x1845 690x596x1845
260 260 260 268
440 440 440 448
42,5 47,7 45,5 48,1
630x1175x1245 630x1175x1245 630x1175x1245 630x1175x1245
94 94 94 94
99 99 99 99
53/63 53/63 54/67 54/67
450/600 450/600 500/800 500/800
2500/3200 2500/3200 2500/3900 2500/3900
210(105+105) 131(65+65) 70(35+35) 76(38+38)
The measurements are performed on a limited number of heat pumps which can cause variations in
the results. Tolerances in the measuring methods can also cause variations.
1)
At A2W35 according to EN 14511 (including circulation pumps and outdoor unit).
2)
At A7W35 according to EN 14511 (including circulation pumps and outdoor unit).
3)
Heat pump with 3 kW auxiliary heater (1-N 1.5 kW).
4)
Heat pump with 6 kW auxiliary heater (1-N 3 kW).
5)
Heat pump with 9 kW auxiliary heater (1-N 4.5 kW).
6)
12 kW auxiliary heater (compressor off).
7)
15 kW auxiliary heater (compressor off).
8)
Nominal flow: heating circuit Δ10K, cooling circuit Δ3K.
9)
Pressure drop that must not be exceeded outside the heat pump without the nominal flow being
reduced.
10
) The values apply to a new heat pump with clean heat exchangers.
11)
Sound power level measured according to EN ISO 3741 at A7W45 (EN 12102).
12)
Sound power level measured according to EN ISO 3741.
13)
Propylene glycol or ethanol may not be used.
14)
Heat pump with 12 kW auxiliary heater.
15)
Heat pump with 15 kW auxiliary heater.
Air to water heat pump
Refrigerant Type
Amount kg
Test pressure MPa
Design pressure MPa
Compressor Type Scroll Scroll Scroll Scroll
Oil POE POE POE POE
Electrical data
3-N~50Hz
Main supply Volt
Rated power compressor kW
Rated power, circ.pumps/fan kW
Auxiliary heater, 5 steps kW
Start current A
Circuit breaker A
Electrical data
1-N~50Hz
Main supply Volt
Rated power compressor kW
Rated power, circ.pumps/fan kW
Auxiliary heater, 3 steps kW
Start current A
Circuit breaker A
Performance
10
Heating capacity
1
kW
COP
1
Heating capacity
2
kW
COP
2
Power input
2
kW
Nominal flow
8
Cooling circuit l/s
Heating circuit l/s
External available pressure
9
Cooling circuit kPa
Heating circuit kPa
Lowest outdoor temperature allowed for compressor start
o
C
Max/min temperature Cooling circuit
o
C
Heating circuit
o
C
Pressure switches Low pressure MPa
Operating MPa
High pressure MPa
Water volume Water heater l
Condensor
l
Evaporator l
Anti freeze media
13
EthyleneGlycol+Watersolutionwithafreezingpointbelow-30°C
Number of units
Indoor unit Dimensions LxWxH mm
Weight empty kg
Weight filled kg
Sound power level
11
dB(A)
Outdoor unit
Dimensions LxWxH mm
Weight empty kg
Weight filled kg
Sound power level, low/high
12
dB(A)
Fan speed low/high rpm
Air flow low/high m
3
/h
Max. pipe length (Cu pipe Ø 28 mm between heat pump and outdoor unit) m