Installation guide

39
VMBME102
Sub menu SERVICE -> INSTALLATION
Used for settings that are set during installation
Menu selection Meaning Factory setting
SWEDISH Language setting for the control computer. SWEDISH
(SVENSKA
NORSK,
SUOMI,
DEUTSCH,
NEDERLANDS,
ENGLISH,
FRANCAIS
POLSKI
DANSK)
SYSTEM
NOTE! The menu selec-
tion in the SYSTEM menu
varies depending on the
selected values. Tip: start
in the top menu and
work downwards.
Sub menu SERVICE -> INSTALLATION -> SYSTEM:
Menu selection Meaning
HEAT SOURCE OUTSIDE AIR
HEATING SYSTEM VLD SYSTEM
COOLING
(Expansion card)
COOLING PASSIVE: OFF/EXTERNAL/INTEGRATED IN HP
COOLING ACTIVE: OFF/EXTERNAL
ROOM SENSOR: 0/1 (Appears if room sensor is installed)(0=controls to a constant
value, 1=controls to the value that the room sensor has)
POOL
(Expansion card)
ON/OFF
SHUNTGROUP
(Expansion card)
ON/OFF
When ON, HEAT CURVE 2 is activated in the INFORMATION menu.
ADD. HEAT CONTROLLED CP: only OFF
0-10V: OFF / EXTERNAL ADDITIONAL HEATER (Expansion card)
FLOW SENSOR: ON/OFF
CURRENT LIMITER: ON/OFF(Expansion card)
PHASE FAULT: OFF / PHASE READING
SERVICETIME NOTE! Only used for test operation. Simulates time 60 times as fast, which
means that the waiting times are eliminated during test operation.
0 = deactivates SERVICETIME
1 = activates SERVICETIME which
speeds up the control computer’s integral cal-
culation and start delay by 60 times.
-
FACTORY SET 0 = starting point, the value returns to zero after a change
R = reset factory settings for radiator system
G = rest factory settings for under floor heating
-
RESET OPERAT. TIME 0 = no reset of operation times
1 = reset operation times to zero
-
CALIBRATION SENSOR Following sensors are in the installation:
OUTDOOR
SUPPLY PIPE
RETURN PIPE
HOT WATER
BRINE OUT
BRINE IN
DEFR SENSOR
0 (interval: -5°C / 5°C)
0 (interval: -5°C / 5°C)
0 (interval: -5°C / 5°C)
0 (interval: -5°C / 5°C)
0 (interval: -5°C / 5°C)
0 (interval: -5°C / 5°C)
0 (interval: -5°C / 5°C)
EXTERNAL INFLUENCE (these parameters affect all sensors except the outdoor
sensor. The parameter compensates for the external influence on the sensor that
is mounted in the heat pump.
0 (at OUTSIDE AIR 5)
(interval: 0 / 20)
LOGTIME Time interval between collection points of temperature history in minutes. The
history graphs always show the 60 last collection points, which means that the
graphs can display history from 1 hour up to 60 hours ago.
(The function is not active if there is an active alarm).
1M (interval: 1M / 60M)
BRINETIME ON Switch on delay for compressor, in seconds. 30S (interval: 10S / 90S)
BRINETIME OFF Switch off delay for brine pump, in seconds. 30S (interval: 10S / 60S)
TOPH. TIME OFF = Deactivates time period for peak heating charging (applies to system D).
ON = Activates time period for peak heating charging (applies to system D).
OFF