Installation guide

61
VMBME102
15 Technical data
DHP-AL
6 8 10 12
Refrigerant type R404A R404A R404A R404A
Refrigerant, kg 0.95 1.45 1.40 1.60
Electrical connection, V 400V 3-N 400V 3-N 400V 3-N 400V 3-N
Rated max output, comp. kW 2.0 2.3 3.6 4.4
Compressor+AH
2) 3) 4)
Electric heating element, kW 3/6/9/12/15 3/6/9/12/15 3/6/9/12/15 3/6/9/12/15
Fuse, A 10
3)
/16
4)
/20
5)
16
3)
/16
4)
/20
5)
16
3)
/16
4)
/20
5)
16
3)
/20
4)
/25
5)
Fuse, A cont. 20
6)
/25
7)
20
6)
/25
7)
20
6)
/25
7)
25
6)
/25
7)
Specified output, kW
1)
6.7/6.1 9.4/8.4 11.3/10.1 13.1/11.9
Efficiency incl. circ.pump and
fan
1)
, COP 3.7/2.5 4.0/2.8 3.7/2.7 3.9/2.8
Specified output, kW
2)
3.2/3.0 4.5/4.0 5.5/5.0 6.5/6.0
Efficiency incl. circ.pump and
fan
2)
, COP 1.9/1.4 2.0/1.6 2.0/1.6 2.0/1.6
Lowest outside temperature for
compressor operation (exterior
stop) -20°C -20°C -20°C -20°C
Fan speed, 2 speed:, rpm 340/650 340/650 575/925 575/925
Air flow, m3/h 1600/3000 1600/3000 3000/4500 3000/4500
Noise level, dB(A)
8)
- 1 m from the unit 44/52 44/52 47/60 47/60
- 8 m from the unit 29/37 29/37 32/45 32/45
- 16 m from the unit 24/32 24/32 27/40 27/40
Nominal flow
- brine, lit/s 0.32 0.49 0.58 0.66
-heat transfer fluid, kPa 0.15 0.21 0.25 0.29
External available pressure
9)
-brine, kPa 79 63 47 57
-heat transfer fluid, kPa 112 110 112 106
Weight, heat pump/outdoor sec-
tion, kg 154/80 154/80 154/80 162/80
Max. Pipe length (Ø28mm) total
between indoor and outdoor
unit, m 60 (30+30) 60 (30+30) 60 (30+30) 60 (30+30)
1)
Tested at outdoor air temperature / heating medium out 7/35°C and 7/50°C (excluding circulation pumps and fan).
2)
Tested at outdoor air temperature / heating medium out -20/35°C and -20/50°C (excluding circulation pumps and fan).
3)
Heat pump with 3 kW auxiliary heater
4)
Heat pump with 6 kW auxiliary heater
5)
Heat pump with 9 kW auxiliary heater
6)
12kW auxiliary heater
7)
15kW auxiliary heater
8)
Noise level measured at SEMKO according to EN ISO 3744
9)
The pressure that must not be exceeded outside the heat pump without falling below the nominal flow.