Installation guide
FP735SI
12
GB
In the Advanced Programming mode, the following parameters can 
be changed:
Parameter1 – Enable/Disable A+B Days
This allows the unit to operate in A+B days. 
A and B days can be grouped arbitrarily: 5+2, 4+3, etc. 
The days do not have to run in sequence.
Press + until parameter 1 is displayed. 
Press V or Λ to select the required setting. 
Note: A+B setting is only possible if operating mode 
5+2 has been set in Advanced Programming.
WARNING: Changing this parameter will reset event 
times to default values.
0 = disabled (default)
1 = enabled
Parameter 2 – Copy functions
This parameter sets the unit to operate with the 
Standard Copy function or the Advanced Copy 
function. 
Press + until parameter 2 is displayed. 
Press V or Λ to select the required setting. 
Note: Advanced Copy setting is only possible if 
operating mode 7 day has been set in Advanced 
Programming.
0 = Standard Copy (default)
1 = Advanced Copy
Parameter 3 – Summer/winter
The Summer/winter parameter makes it possible 
to let the unit change between summer and winter 
period automatically or manually. The parameter can 
also disable the change between summer and winter. 
Press + until parameter 3 is displayed.
Press V or Λ to select the required setting.
0 = disable summer/winter change 
1 = enable manual summer/winter change
2 = enable automatic summer/winter change (default)