4. Technical settings
4.3 Adjustments for over/undersized radiators
The factory setting is P2.
Use P1 if the radiator appears oversized for the room.
Use P3 if it is undersized.*
Press for at least 3 seconds until
M is displayed.
Press until Pb is displayed. Press
Select P1, P2 or P3 using the arrow keys,
and exit using
*The frequency of P1, P2 and P3 regulation
varies to compensate for radiator over/under
sizing.
4.4 Reset to factory settings
Remove the battery cover and take out one battery.
Press and hold for approx. 5 seconds, while
reinserting the battery.