Instruction Manual
Service guide | Disassembling and assembling PAHT and PAHT G 50-90
10
180R9172 | 521B1092 | AX234886502908en-000402 | 2022.10
2. Parts needed for assembly of the pump.
4. Mount O-ring in port ange.3. Mount 1 guide pin in housing.
1. Tools required for assembly of the pump.
1. Lubrication:
• To prevent seizing-up, lubricate all
threads with PTFE lubrication type.
• O-rings inside pump may be lubricated
only with clean ltered water.
• O-rings for port ange, mounting ange
and ushing valve must be lubricated.
• It is important to lubricate ALL parts to
be assembled with clean ltered water
(Especially all PEEK parts).
WARNING:
Do not use silicone when assembling the
pump. Do not reuse disassembled O-rings;
they might be damaged. Always use new
O-rings.
Important:
It is essential that the pump is serviced in
conditions of absolute cleanliness. All parts
must be absolute clean before mounting.