Connecting the inverters
SMA
Solar-Log
1000/500/200
Installation 19 of 268
4.2.2 SMA connection using special RS485 piggyback card
Overview
Interface not integrated. retrofit the special RS485 piggyback card
Where to connect: Terminal strip inside the inverter on the piggyback
Communication address does not have to be allocated.
4 pin wiring
Work steps
Switch off the inverters and SolarLog™; Page 17
Install the Special RS485 piggy back in the inverter
Connect inverters to the Solar-Log
Connect the inverters to each other
Installing the special RS485 piggyback in inverters
Procedure
1 Open the inverter as described in the inverter instructions.
2 Insert the piggy back with the bottom plug connector left aligned on the
control board of the inverter ( Figure 10, left)
The word bottom printed on the control board must be visible on the bot-
tom left ( Figure 10, right).
Figure 10: Control board before and after installation of the piggy back