Installation manual

Solar-Log1000: Configuration at the unit
Configuring the inverter data (Basic/Inverter)
Solar-Log
1000/500/200
Installation 231 of 268
Procedure
To configure the limit values for fault messages, and the messaging in general:
1 Select the message form (Relay, EMail and/or SMS).
2 Touch the input box beside From deviation of
The virtual keyboard is opened.
3 Enter the lower limit percentage of generator power at which a fault is rec-
ognised, and confirm with OK
4 Touch the input box beside Starting from .. of malfunction
The virtual keyboard is opened.
5 Enter the lower limit percentage of the fault duration at which a fault is rec-
ognised, and confirm with OK
6 Touch the input box beside Max. number of messages per day
The virtual keyboard is opened.
7 Enter the maximum number of messages to be sent per day and confirm
with OK
8 Touch Save, then Next to go to the next dialogue.
Configuring the graph display
If configuring through the display, only the Y-axis (power output) of the graph for
the yield data can be set; if configuring from a PC, both the Y-axis (Page 167)
and the X-axis (time of day) can be set (Page 170).
Nothing usually has to be changed here, as Solar-Log
1000
automatically calcu-
lates the values for the generator power input. However, these values can be
adapted to your own data.
Dialogue boxes
Day, Month, Year, All years
For each period specified, the maximum value to be plotted can be entered
in kW (in W for a day).
The graph on the display and on the PC represents these values on the Y axis.
Changes become effective when a new graph is displayed, or after a dis-
played graph is updated.
Procedure
To set the representation on the Y-axis:
1 Touch the required input box beside Day, Month, Year and/or All years
The virtual keyboard is opened.
2 Enter the maximum value to be represented on the Y-axis and confirm with OK
3 Touch Save