Technical data

8.1.3. Status
Menu Structure - Status
Display Functions Description
[0] Ambient Conditions Only applicable if sensors are connected
[0] Irradiance: 1400W/m
2
Irradiance as detected by sensor. NC if not connected
[0] PV module temp: 100
o
C
PV module temperature as detected by sensor. NC if not connected
[0] Ambient temp: 20
o
C
Ambient temperature as detected by sensor. NC if not connected
[0] Irr. sensor temp: 32
o
C
Irradiation sensor temperature as detected by sensor. NC if not connected
[0] Photovoltaic
[0] Present values
[0] PV input 1
[0] Voltage: 1000V Voltage detected at PV input 1
[0] Current: 15.0 A Current detected at PV input 1
[0] Power 10000 W Power detected at PV input 1
[0] PV input 2
[0] Voltage: 1000V
[0] Current: 15.0 A
[0] Power 10000 W
[0] PV input 3 Not visible if inverter only has 2 PV inputs.
[0] Voltage: 1000V
[0] Current: 15.0 A
[0] Power 10000 W
[1] Maximum values
[1] PV input 1
[1] Voltage: 1000V
[1] Current: 15.0 A
[1] Power 10000 W
[1] PV input 2
[1] Voltage: 1000V
[1] Current: 15.0 A
[1] Power 10000 W
[1] PV input 3 Not visible if inverter only has 2 PV inputs.
[1] Voltage: 1000V
[1] Current: 15.0 A
[1] Power 10000 W
[0] Insulation Resistance
[0] Resistance: 45 MΩ
PV insulation resistance at start-up
[1] Minimum: 45 MΩ
[1] Maximum: 45 MΩ
[0] PV Input Energy
[0] Total: 1234567 kWh Daily production of all PV input
[0] PV1: 123434 kWh Daily production of PV input 1
[0] PV2: 123346 kWh Daily production of PV input 2
[0] PV3: 123345 kWh Daily production of PV input 3. Not visible if inverter only has 2 PV inputs.
[0] PV Configuration
[0] PV input 1:
Configuration of PV input 1. The configuration is only shown when the in-
verter is in Connecting or On grid mode.
[0] PV input 2:
[0] PV input 3: Not visible if inverter only has 2 PV inputs.
Table 8.3: Menu Structure - Status
8. User Interface
62 L00410582-01_02