4 VIILC102 © Danfoss A/S (Dept./Init.), 2014-05
Technical data
Pressure drop diagram
0
10
20
30
40
50
60
70
80
90
100
110
120
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1 1,2 1,3 1,4 1,5 1,6
Pressure drop (KPa)
Coilow (l/sec)
WT-T 300 WT-T 500
WT-T 300 500
Corrosion protection stainless stainless
Volume, hot water heater litre 300 500
Volume, coil litre 18 24
Length, coil m 30 39
Heating surface, coil 2,9 3,7
Max. pressure, hot water heater bar/MPa 10 10
Max. pressure, coil bar/MPa 10 10
Max. immersion heater length mm 460 570
Height (incl. feet) mm 1780 1850
Net weight kg 63 88
Immersion heater, max. output kW 6 9
Safety valve
The safety valve must be inspected regularly.
Ease the safety valve lever slightly to release some water through the overow pipe. This must be carried out at least 4 times a
year. It is quite normal for the safety valve to let out small amounts of water when the water tank is being charged.
If the valve does not work satisfactory, it must be replaced.
If there is a risk of freezing, the water heater must be drained.
In the event of malfunctions - contact the installer.