Installation guide
4 VIILC102 © Danfoss A/S (Dept./Init.), 2014-05
Technical data
Pressure drop diagram
0
10
20
30
40
50
60
70
80
90
100
110
120
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1 1,2 1,3 1,4 1,5 1,6
Pressure drop (KPa)
Coilow (l/sec)
WT-T 300 WT-T 500
WT-T 300 500
Corrosion protection stainless stainless
Volume, hot water heater litre 300 500
Volume, coil litre 18 24
Length, coil m 30 39
Heating surface, coil m² 2,9 3,7
Max. pressure, hot water heater bar/MPa 10 10
Max. pressure, coil bar/MPa 10 10
Max. immersion heater length mm 460 570
Height (incl. feet) mm 1780 1850
Net weight kg 63 88
Immersion heater, max. output kW 6 9
Safety valve
The safety valve must be inspected regularly.
Ease the safety valve lever slightly to release some water through the overow pipe. This must be carried out at least 4 times a
year. It is quite normal for the safety valve to let out small amounts of water when the water tank is being charged.
• If the valve does not work satisfactory, it must be replaced.
• If there is a risk of freezing, the water heater must be drained.
• In the event of malfunctions - contact the installer.