Flowlight Booster Pump Instruction Manual

Notes to Installer:
This pump pulls water in by suction. The inlet plumbing
must offer a very free flow, like a drain pipe in reverse.
The pump will be very noisy if intake is restricted or
blocked by air pockets or being undersized.
This pump tolerates NO solid debris.
A disposable cartridge filter is required at the intake.
NEVER run this pump without a filter.
Do not omit the intake screen.
After the first test run, check the screen
and remove any plumbing debris.
The manual contains important maintenance
information, and is the property of the pump owner.
Please give it to them when you are finished!
NOISE = CAVITATION = RAPID PUMP WEAR
FIX THE PROBLEM!!!
Failure to install a fuse or breaker equal or less than the
motor's Max Amp rating will void your warranty.
See Page 3
See Page 14
See Page 2
See Page 6
Flex hose
Pressure
Gauge
Pressure
Switch
Ball Valve
Tank Tee
Foot Valve
required if tank
is below pump
Pressure Tank
40 Gallon
Minimum recommended size.
Adjust pre-charge to
2-3 psi below cut-in pressure
Turn CW to raise
CUT ON & OFF
pressure
Supply
to House
Storage
Tank
Turn CW to
raise OFF pressure
Ball Valve
10" Filter
Capsule
DSP-11033
with 10 micron
Filter set
DSP-11034
R 1.1
Optional Dry Run Protection
DSP-02527 for Booster Pumps
Debris
Screen
www.dankoffsolar.com
+
EZ Install Kit
DSP-11012
Priming Port
if pump is above
water source
A STEADY BUZZING SOUND indicates
EXCESSIVE SUCTION.
An UNSTEADY BUZZING SOUND
indicates a LEAK IN THE SUCTION LINE.
See Page 14 for troubleshooting tips
Air vent
Low voltage systems require larger wire than 115v.
See Dankoff Universal Wire Sizing Chart for assistance.
Copyright Dankoff Solar 2004
©
2/2005
FlowLight
Booster Pump
EZ Install Diagram