PRESSURIZED POND FILTER MODELS ITEM # No UV 2700 5500 8000 16000 05610 05620 05630 05640 With UV 120V 230V 05615 05617 05625 05627 05635 05637 05645 ZG400 revD 1/18 CARE AND OPERATING INSTRUCTIONS 1
WARNING! PONDS ARE DANGEROUS TO SMALL CHILDREN! NEVER LEAVE CHILDREN UNSUPERVISED NEAR A POND.
Filter CHOOSE THE CORRECT PUMP Pumps up to: Your Pressurized Filter System works best within a certain range of flow Model 3000 GPH/11350 LPH and pressure. See Table. Exceeding these values will cause leakage or 2700 5500 6000 GPH/22700 LPH breakage of the filter or its components and void the warranty.
SECURE COVER WITH CLAMP Once cover is pressed down evenly, place the clamp around the drum and cover flanges and pull the open end closed. Note that it is best to position the open end of the clamp away from hose connections for easy access to the tightening knob once hoses are attached. Insert hex bolt through opening with hex recess and push through to opening on other end of clamp. Attach the tightening knob to hex nut and turn until clamp closes completely.
VALVE POSITIONS The valve has 7 positions. They are numbered for identification. CAUTION: Never lift filter using the valve position handle. CAUTION: Always turn off pump when changing valve positions. Change valve positions by pressing down on handle, rotating until pointer points to desired number and release. (In this illustration the pointer is at position 6.) Check that handle is not in between settings when releasing handle.
UV CLARIFIER OPERATING INSTRUCTIONS: QUARTZ SLEEVE DETAIL BLACK NECK If your pressure filter was supplied with an NOTE POSITION OF FLAT GASKET AND O-RING UV clarifier or if you are adding a UV FLAT GASKET Clarifier, note the following: SEATS ON TOP OF QUARTZ The UV Clarifier will not light up when SLEEVE removed from the pressure filter cover. It incorporates a safety switch to disable power when not assembled.
WINTERIZATION CAUTION: During harsh winters, water left in the drum may freeze, expand and crack the drum. If necessary, the filter can be drained and winterized at the end of the season. If you live in an area that doesn’t experience freezing temperatures, you may never need to do this. To empty the water from the filter drum, it is not necessary to open the filter. 1) Turn off the pump and disconnect the power source to the UV. 2) Turn the Valve to position #7 WINTER.
/' TROUBLE SHOOTING Subscribe to our YouTube Channel and view all of our Clearguard videos ' SYMPTOM POSSIBLE CAUSE Filter output is Filter Pad is clogged. Remove rinse and replace filter pad. Media needs cleaning. Backwash filter. See BACKWASH CYCLE. Pump intake is clogged, Pump is undersized or requires maintenance. Check pump and clear debris. Use a Pump Bag around pump to prevent future clogging. See pump manual. Discharge is clogged.
PARTS LISTING For reference only, all parts are not available individually.
WARRANTY 12 ZG400 RevD 1/18 Pondmaster Filtration systems are warranted against failure due to defects in materials and/or workmanship for one year from date of purchase. This warranty covers defects occurring under normal use and applies to the original purchaser at retail and may not be transferred. The warranty and remedies set forth herein are conditional upon proper installation, use, maintenance, storage, and conformance with the applicable use. It will be based upon Danner Mfg.