MOBILE HOME INSTALLATION
CAUTION: DO NOT INSTALL STOVE IN SLEEPING ROOM
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR,
CEILING/ROOF MUST BE MAINTAINED!
Your
GLOW BOY”
Shop and Home Heater has been tested and listed for mobile home installation. It may be
installed in a mobile home as a "Free Standing Stove", a "Hearth Stove", see detailed installation and clearance
requirements in these sections as they imply there.
In addition to all previously detailed installation requirements, mobile home installations must
meet the following requirements:
Permanently bolt your stove to the floor, (A).
Electrically ground your stove or the pedestal to the steel frame of the home. Use a number 8 gauge copper
wire, (B), or equivalent.
The stove must have a permanent outside air source with a ¼ inch screen over the inlet.
For transportation all chimney/vent above the mobile home must be removed.
Chimney/PL Vent must be 3” or 4” PL Vent and must extend a minimum or 36” above the roofline of the
mobile home and must be installed using a UL/ULC listed ceiling fire stop and rain cap.
Note: When moving your Mobile Home, all exterior venting must be removed while Mobile Home
is being relocated. Upon completion of relocation all venting must be reinstalled and securely
Floor Pad
Floor
Frame
A
(bolts)
B
(ground wire)
A
Floor Pad
B
Combustion Air Intake
C
Fresh Air Duct
D
Fresh Air Hood
E
Stove Exhaust
F
Pipe Adapter
G
Clean Out Tee
H
Tee Support Bracket
I
Pipe
J
Firestop Spacer / Ceiling Support
K
Roof Flashing / Storm Collar
L
Rain Cap