PERIODIC MAINTENANCE CONTINUED
INSPECT AND CLEAN THE CHIMNEY: [ELECTRICAL CORD UNPLUGGED] Under some
conditions fly ash build up in the chimney system may occur rapidly. The fly ash will collect in the exhaust
venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup,
shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the
exhaust venting system. Check the clean out tees and elbows in the exhaust system periodically to determine
the cleaning schedule. To remove dust from the vent pipe, tap lightly on the pipe to dislodge any loose ash.
Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as possible.
3 or 4-inch chimney brushes are available for chimney cleaning. If the exhaust system has a screen on it,
frequently clean the screen. A plugged screen will shut off combustion air and cause a fire to die or burn
poorly.
PAINTED SURFACES: Painted surfaces may be wiped down with a damp cloth. If scratches appear or
you wish to renew your paint, contact your Dealer to obtain a can of Satin Black (“Stove Bright”) paint.
Tip: use a hair dryer to warm the surface prior to touching up the paint,
this helps to reduce paint runs.
Note: Do not use any other brand than “Stove Bright” as they may not be compatible.
NOTE: YourGlow Boy” Dealer may offer a periodic stove cleaning service. Check with them on timing
and cost of this service.
FALL START UP: Prior to lighting the first fire check the outside area around the exhaust and air intake
systems for obstructions. Clean the screens on the exhaust system and the outside air intake pipe. Turn all
controls on to make sure they are working prior to lighting the first fire. Clean and remove fly ash from exhaust
venting. Our local Authorized Dealer should have 3” and 4” chimney brushes available. This is also a good
time to give the entire stove a good cleaning throughout.
SPRING SHUTDOWN: [COLD
STOVE AND COLD ASHES ONLY].
After the last burn in the spring remove
pellets from the hopper and the auger.
Scoop out the pellets then run the
auger until the hopper is empty and
pellets stop flowing. Vacuum out the
hopper. Thoroughly clean the burn
grate, burn box, ash pit and ash traps.
It’s desirable to spray the inside of the
cleaned hopper with an aerosol
silicone spray if your stove is in a high
humidity area. The exhaust system
should be thoroughly cleaned.
YEARLY SERVICING: A yearly
servicing and cleaning by your
Authorized “Glow Boy” Dealer is
recommended. A fee may be charged
for this service.
Figure 30
Window
Burn Pot
Burn Grate
Heat Tubes
Tu be Sc rap er
Ash Pit
Hopper
Fan Motors
Auger
Exhaust
Air Intake
Auger Motor
Base
Hopper Lid
(120 lbs.)
(300 lbs.)