Table1 (Remote On/Off Control)
Remote On/Off Control
Parameter Min Max
Supply On Under 1 VDC or Open Circuit
Supply Off 4VDC
Standby Input Current 0.2mA
Control Input Current(On) -0.5mA
Control Input Current(Off) 5mA
Control Common
Referenced to -Vin
INPUT FUSE SELECTION GUIDE
4.5-6.0V or 4.5-9V
INPUT VOLTAGE(VDC)
9-18V or 9-36V
INPUT VOLTAGE(VDC)
18-36V or 18-72V
INPUT VOLTAGE(VDC)
36-72V
INPUT VOLTAGE(VDC)
3000mA Slow-Blow Type 1500mA Slow-Blow Type 800mA Slow-Blow Type 400mA Slow-Blow Type
DC-DC
CONVERTER
+Vin
-Vin
+Vout
-Vout
OUTPUT
Fuse
INPUT
Note: Certain applications may require the installation of external fuse in front of the input.
CW SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the CW series.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 100KHz is required.
External output capacitance is not required for operation, however it is recommended that 10uF
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.
Additional output capacitance may be added for increased filtering, but should not exceed 1000uF.
We Can Offer EMC-Filter According To EN55011/22 Class B.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.