Datasheet
DANUBE
http://www.danube.com.tw
2010/12/01
1
FEATURES
SINGLE IN LINE PACKAGE
UP TO 1W UNREGULATED OUTPUT POWER
100% BURN IN
HIGH EFFICIENCY
INTERNAL SMD TECHNOLOGY
LOW COST
NO HEATSINK REQUIRED
UL 94V-0 PACKAGE MATERIAL
CUSTOM SOLUTIONS AVAILABLE
RoHS COMPLIANT
3 YEARS WARRANTY
OUTPUT SPECIFICATIONS INPUT SPECIFICATIONS
Voltage Set-point Accuracy
+/-2% max Input Voltage Range +/-10% max
Temperature Coefficient +/-0.05%/
°
C Input Filter Capacitor Typ
Ripple & Noise(20MHz BW)
1
100mVp-p max Input Reflected Ripple Current
50mAp-p max
Line Regulation
2
+/-1.2% max Protection Fuse Recommended
Load Regulation
3
+/-8% max
Load Regulation
4
+/-12% max
Minimum Load 10% of Full Load
GENERAL SPECIFICATIONS
Short Circuit Protection Momentary Efficiency 70%-82%
Isolation Voltage
5
1500-3000 VDC
Isolation Resistance 10
9
ohms min
Isolation Capacitance 80pF max
Switching Frequency 100KHz Typ
ENVIRONMENTAL SPECIFICATIONS
MTBF
6
>2,000,000 Hours
Operating Temperature -25
°
C to +71
°
C Weight 1.3g Typ
Case Temperature +90
°
C max
Case Material Non-Conductive Plastic
Storage Temperature -55
°
C to +125
°
C Case Size 11.7mm*6.0mm*10.2mm
Humidity 95% max 11.7mm*7.5mm*10.1mm
Cooling Free-Air Convection Conducted Emissions EN55022 Class A
Radiated Emissions EN55022 Class B
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD AND 25
°
C UNLESS OTHERWISE NOTED.
1
Measured with 1uF ceramic capacitor connect to the output pins.
2
Line Regulation is for a 1.0% change in input Voltage.
3
Load Regulation is for output load current change from 20% to 100%.
4
Load Regulation is for output load current change from 20% to 100% when input voltage is 3V and 3.3V.
5
1500VDC for 10 seconds,3000VDC for 3 seconds.
6
MIL-HDBK-217F @25
°
C , Ground Benign.
MU
SERIES
1W UNREGULATED