Datasheet

DANUBE
http://www.danube.com.tw
2009/06/04
1
FEATURES
z SINGLE IN LINE PACKAGE
z UP TO 1W REGULATED OUTPUT POWER
z 100% BURNED IN
z EFFICIENCY UP TO 53%
z INTERNAL SMD TECHNOLOGY
z NO EXTERNAL COMPONENTS REQUIRED
z LOW COST
z 1500VDC ISOLATION
z UL 94V-0 PACKAGE MATERIAL
z CUSTOM SOLUTIONS AVAILABLE
z RoHS COMPLIANT
z 3 YEARS WARRANTY
OUTPUT SPECIFICATIONS
Voltage Setpoint Accuracy
+/-3% max
Input Voltage Range +/-10% max
Temperature Coefficient
+/-0.05%/°C
Input Filter Capacitor Typ
Ripple & Noise(20MHz BW)
1
100mVp-p max Protection Fuse Recommended
Line Regulation
2
+/-1% max
Load Regulation
3
+/-1% max
GENERAL SPECIFICATIONS
Minimum Load 10% of Full Load Efficiency 50% min
Short Circuit Protection Current Limit Protection Isolation Voltage
4
1500 VDC min
Short Circuit Restart Automatic Isolation Resistance 10
9
ohms min
Transient Response
5
100uS max Isolation Capacitance 80pF max
Switching Frequency 100KHz min
MTBF
6
>1,800,000 Hours
ENVIRONMENTAL SPECIFICATIONS
Weight 2.3g Typ
Operating Temperature -25
°C to +71
°C Case Material Non-Conductive Plastic
Storage Temperature -55
°C to +125
°C Case Size 19.6mm*7.1mm*10.2mm
Humidity 95% max Conducted Emissions EN55022 Class A
Cooling Free-Air Convection Radiated Emissions EN55022 Class A
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25
°C UNLESS OTHERWISE NOTED.
1
Measured with 1uF ceramic capacitor connect to the output pins.
2
High Line to Low Line.
3
Load Regulation is for output load current change from 10% to 100%.
4
For 10 seconds.
5
25% Step Load Change.
6
MIL-HDBK-217F @25
°C , Ground Benign.