DEH-600wp, DEH-1000wp, DEH-1700wp, DEH-2000wp, DEH-2500wp, DEH-4000wp.
R Please read this manual carefully before using your dehumidifier and keep it well. If you have any question of using your dehumidifier please contact your local dealer. 1 www.danvex.
R CONTENT Introduction................................................................................................................................3 Safety precautions.....................................................................................................................4 Dehumidifier description............................................................................................................6 Electric circuit diagrams...............................................................
R INTRODUCTION MODELS: DEH-600wp DEH-1000wp DEH-1700wp DEH-2000wp DEH-2500wp DEH-4000wp All the dehumidifiers described in this manual are designed to adjust the indoor relative humidity from 40% RH to 99 % RH at the ambient temperature from +1O°C up to +32°C. 3 www.danvex.
R SAFETY PRECAUTIONS Read these safety precautions carefully WARNING before the humidifier operation. Meanings of symbols used in this manual are shown below. Don't do it under any circumstances Follow the instruction by all means There should be no any damages in the power cord and its extensions. Remove any dirt from the power cord. If dirt adheres to the power plug or the plug connection with the socket is nontight, it may cause the fire or electric shock.
R SAFETY PRECAUTIONS WARNING Do not pull the power cord. It can cause the short circuit and lead the Do not apply an insecticide or flammable spray. It may cause the fire or deformation of the electric shock or fire. Prior to the unit cleaning it should be switched. Disconnect the power cord from the electric mains. housing. Do not clean the unit with water. It may cause the electric shock.
R DEHUMIDIFIER DESCRIPTION Dehumidifiers: DEH-600wp and DEH-1000wp Control panel Air outlet Power cord LEFT SIDE FRONT SIDE Drain hose Air inlet Base www.danvex.
R DEHUMIDIFIER DESCRIPTION Dehumidifiers: DEH-1700wp и DEH-2000wp Air outlet Control panel Power cord LEFT SIDE FRONT SIDE Drain hose RIGHT SIDE Air inlet Base 7 www.danvex.
R DEHUMIDIFIER DESCRIPTION Dehumidifiers: DEH-2500wp и DEH-4000wp Control panel Air outlet Power cord LEFT SIDE FRONT SIDE Drain hose Air inlet Base www.danvex.
R DEHUMIDIFIER DESCRIPTION Dehumidifiers: 1. Wall mounting bracket, 2 pcs. per dehumidifier set. 2. Anchor bolt, 6 pcs. per humidifier set (used for unit wall mounting). 3. Mounting screw, 4 pcs. per humidifier set (used for unit wall mounting). 4. Floor foot, 4 pcs. per humidifier set (used for unit floor mounting). 5. Wheel, 4 pc. per humidifier set (used for unit mobile mounting). 6. Drain hose, 1 pc. per humidifier set. 9 www.danvex.
R ELECTRIC CIRCUIT DIAGRAMS DEH-600wp, DEH-1000wp Single phase (1PH/5o Hz) Humidity sensor Internal temperature sensor To display PCB External temperature sensor Transformer Main controller PCB High pressure protection Low pressure protection Power supply Fan motor Compressor www.danvex.
R ELECTRIC CIRCUIT DIAGRAMS DEH-1700wp, DEH-2000wp Single phase (1PH/50 Hz) Humidity sensor To display PCB Internal temperature sensor External temperature sensor Transformer Main controller PCB High pressure protection Low pressure protection Power supply Fan motor Pressure control valve Compressor 11 www.danvex.
R ELECTRIC CIRCUIT DIAGRAMS DEH-2500wp, DEH-4000wp Three phases (3PH/50 Hz) Humidity sensor Internal temperature sensor External temperature sensor Main controller PCB Transformer Low pressure protection High pressure protection PCB protection phases sequence To display PCB Pressure control valve Fan motor Red Black White Gray Green Compressor www.danvex.
R INSTALLATION INSTRUCTIONS WHEELS INSTALLATION 2. How to install the dehumidifier on the floor: Step 1: Put the dehumidifier on the platform as it's shown on the picture. There are 4 holes on the base. Step 2: Install the floor feet in the base holes. Step 3: Move the dehumidifier to the necessary place. Step 4: Adjust the feet height as required. Step 5: Connect the drain hose to the dehumidifier. Switch the dehumidifier on for the trial operation.
R INSTALLATION INSTRUCTIONS WHEELS INSTALLATION 3. How to install the dehumidifier on the wall: Step 1: Choose the right installation position for the wall mounting according to the size of mounting holes and position of the wall bracket holes. The installation position should guarantee the dehumidifier horizontal position. Drilling places should be marked. Step 2: Use the percussive drilling machines to drill holes with 8 cm±0.5cm depth.
R STARTUP AND OPERATION Fault signal lamp Humidity level Electric heater signal lamp FUNCTIONS OF THE CONTROL PANEL AND REMOTE CONTROL UNIT 1. When electric supply is connected the display will show the current ambient humidity. i/ e. = indoor air humidity is 60%. Defrosting signal lamp RCU signal receiver UP button 2. Buttons and turn the dehumidifier on and off. DOWN button ON/OFF button 3. Buttons and are used to set the desired humidity level.
R ERROR MESSAGES IF THE HUMIDIFIED STOPS WORKING THE DIPLAY WILL SHOW THE ERROR MESSAGE E0: The defrosting system is not working correctly. Please contact your dealer. E1: The dehumidifying sensor is not working correctly. Please contact your dealer. E2: The external temperature sensor is not working correctly. Please contact your dealer. E3: Ambient temperature is over the working temperature. If the ambient temperature is over 32°C or below 10°C, it will display error message E3 too.
R ERROR MESSAGES IF THE HUMIDIFIED STOPS WORKING THE DIPLAY WILL SHOW THE ERROR MESSAGE E5 (1): It is displayed when the unit is connected to the power for the first time and the phase error is found. Please contact your dealer. E5 (2): It is displayed during the running process and indicates that the current is exceeded or the phase is lacking. Clean the evaporator and condenser. Please contact your dealer. E6: Indicates the low pressure level. Please contact your dealer.
R DEHUMIDIFIER MAINTENANCE When you are going not to use the dehumidifier for a long time. When you want to use the dehumidifier. Start the air dehumidifying process for 3 – 4 hours installing the humidity level at 80% to dry the dehumidifier inside. Ensure that the air inlet and air outlet are not blocked. Turn off the dehumidifier and then the disconnect the plug from the socket. Ensure that the grounding wire is connected properly. WARNING Use the ground.
R TECHNICAL SPECIFICATIONS NOTE: 1. Rated noise value is detected in the laboratory. 2. In case of the difference of the specifications indicated in the above table and the specifications indicated directly on the nameplate it's necessary to use the specifications of the nameplate. 3. Test data: ambient temperature is 30oC, and the ambient humidity is 80%RH. SPECIAL INSTRUCTIONS: 1. Customer should contact the special service department for the qualified installation and repair. 2.
R Warranty obligations DanVex warrants that all the equipment parts will answer the technical requirements for 12 months from the date of delivery (warranty period). The warranty does not cover wearable parts such as filters. The warranty covers the defects in workmanship and materials. During the warranty period DanVex repairs and replaces the part having a defect of material or an manufacturing error.