Containment/Clean up:
Observe all personal protection equipment recommendations described in Sections 5 and 8.
Wipe up or scrape up and contain for salvage or disposal. Clean area as appropriate since
spilled materials, even in small quantities, may present a slip hazard. Final cleaning may
require use of steam, solvents or detergents. Dispose of saturated absorbant or cleaning
materials appropriately, since spontaneous heating may occur. Local, state and federal laws
and regulations may apply to releases and disposal of this material, as well as those materials
and items employed in the cleanup of releases. You will need to determine which federal,
state and local laws and regulations are applicable. Sections 13 and 15 of this MSDS provide
information regarding certain federal and state requirements.
Note: See section 8 for Personal Protective Equipment for Spills. Call (989) 496-5900, if additional information is
required.
7. HANDLING AND STORAGE
Use with adequate ventilation. Product evolves acetic acid (HOAc) when exposed to water or humid air. Provide
ventilation during use to control HOAc within exposure guidelines or use respiratory protection. Avoid eye contact.
Keep container closed and store away from water or moisture.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Component Exposure Limits
CAS Number Component Name
Exposure Limits
17689-77-9 Ethyltriacetoxysilane
See acetic acid comments.
4253-34-3 Methyltriacetoxysilane
See acetic acid comments.
Acetic acid is formed upon contact with water or humid air. Provide adequate ventilation to control exposures within
guidelines of OSHA PEL: TWA 10 ppm and ACGIH TLV: TWA 10 ppm, STEL 15 ppm.
Engineering Controls
Local Ventilation: None should be needed.
General Ventilation: Recommended.
Personal Protective Equipment for Routine Handling
Eyes:
Use proper protection - safety glasses as a minimum.
Skin:
Wash at mealtime and end of shift. Contaminated clothing and shoes should be removed as
soon as practical and thoroughly cleaned before reuse. Chemical protective gloves are
recommended.
Suitable Gloves:
Silver Shield(R). 4H(R).