| SECTION 5 - FIRE FIGHTING MEASURES |
|-------------------------------------------------------------------------|
AUTOIGNITION TEMPERATURE: N.E.
EXTINGUISHING MEDIA: CO2 DRY CHEMICAL FOAM WATER FOG
UNUSUAL FIRE AND EXPLOSION HAZARDS: Combustible. Vapor from this material
will readily at temperatures above 150• F. if an ignition source is
present. Vapors may form an explosive mixture with air at tempertures above
150• F. Containers may explode if exposed to extreme heat. Eliminate
sources of ignition: heat, electrical equipment, sparks, and flames. Do
not put in contact with oxidizing or caustic materials.
SPECIAL FIREFIGHTING PROCEDURES: Full protective equipment, including
self-contained breathing apparatus, is recommended to protect from
combustion products. Cool exposed containers with water.
|-------------------------------------------------------------------------|
| SECTION 6 - ACCIDENTAL RELEASE MEASURES |
|-------------------------------------------------------------------------|
SPILL OR LEAK PROCEDURES: Dike spill area. Immediately eliminate sources
of ignition. Use absorbent material or scrape up dried material and place
into containers.
|-------------------------------------------------------------------------|
| SECTION 7 - HANDLING AND STORAGE |
|-------------------------------------------------------------------------|
HANDLING INFORMATION: KEEP OUT OF REACH OF CHILDREN. Avoid skin and eye
contact. Avoid breathing vapors. Use only in a well ventilated area.
STORAGE INFORMATION: Store away from caustics and oxidizers. Keep away
from heat, spark, and flame. Keep containers tightly closed when not in
use. Keep containers from excessive heat and freezing. Do not store at
temperatures above 120 degrees F.
OTHER PRECAUTIONS: Intentional misuse by deliberately concentrating and
inhaling vapors may be harmful or fatal. Do not take internally.
|-------------------------------------------------------------------------|
| SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION |
|-------------------------------------------------------------------------|
ENGINEERING CONTROLS: Provide sufficient mechanical ventilation (local or
general exhaust) to maintain exposure below PEL and TLV. Vapors are
heavier than air and will collect in low areas. Check all low areas
(basements, sumps, etc.) for vapors before entering.
RESPIRATORY PROTECTION: If 8 hour exposure limit or value is exceeded for
any component, use an approved NIOSH/OSHA respirator. Consult your safety
equipment supplier and the OSHA regulation, 29 CFR 1910.134 for respirator
requirements. A respiratory protection program that meets OSHA 1910.134 and
(Continued on Page 4)