MSDS

Product Name: PLASTIC WOOD
Revision Date: 3/3/2004 Page 3
|-------------------------------------------------------------------------|
| SECTION 5 - FIRE FIGHTING MEASURES |
|-------------------------------------------------------------------------|
FLASH POINT: <20 F LOWER EXPLOSIVE LIMIT: N.A.
(SETAFLASH CLOSED CUP) UPPER EXPLOSIVE LIMIT: N.A.
AUTOIGNITION TEMPERATURE: N.E.
EXTINGUISHING MEDIA: CO2 DRY CHEMICAL FOAM
UNUSUAL FIRE AND EXPLOSION HAZARDS: Extremely Flammable. Material will
readily ignite at room temperatures. Containers may explode if exposed to
extreme heat. Eliminate sources of ignition: heat, electrical equipment,
sparks, and flames. Do not put in contact with oxidizing or caustic
materials.
SPECIAL FIREFIGHTING PROCEDURES: Full protective equipment, including
self-contained breathing apparatus, is recommended to protect from
combustion products. Cool exposed containers with water.
|-------------------------------------------------------------------------|
| SECTION 6 - ACCIDENTAL RELEASE MEASURES |
|-------------------------------------------------------------------------|
SPILL OR LEAK PROCEDURES: Scrape up dried material and place into
containers.
|-------------------------------------------------------------------------|
| SECTION 7 - HANDLING AND STORAGE |
|-------------------------------------------------------------------------|
HANDLING INFORMATION: KEEP OUT OF REACH OF CHILDREN. Avoid skin and eye
contact. Avoid breathing vapors. Use only in a well ventilated area.
STORAGE INFORMATION: Store away from caustics and oxidizers. Keep
containers tightly closed when not in use. Keep containers from excessive
heat and freezing. Do not store at temperatures above 120 degrees F.
OTHER PRECAUTIONS: Intentional misuse by deliberately concentrating and
inhaling vapors may be harmful or fatal. Do not take internally.
|-------------------------------------------------------------------------|
| SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION |
|-------------------------------------------------------------------------|
ENGINEERING CONTROLS: Provide sufficient mechanical ventilation (local or
general exhaust) to maintain exposure below PEL and TLV. Vapors are heavier
than air and will collect in low areas. Check all low areas (basements,
sumps, etc.) for vapor before entering. Provide eyewash and solvent
impervious apron if body contact may occur.
(Continued on Page 4)
---------------------------------------------------------------------------