Programming instructions
Chapter 14 Simultaneous Buffered Waveform Acquisition and Generation
LabVIEW Data Acquisition Basics Manual 14-6
©
National Instruments Corporation
Hardware Triggered
Figure 14-4 shows the diagram of the Simul AI/AO Buffered Trigger
(legacy MIO) VI located in
labview\examples\daq\anlog_io\
anlog_io.llb
.
Figure 14-4.
Simultaneous Input/Output Using the
Simul AI/AO Buffered Trigger (Legacy MIO) VI
The only difference between this example VI and the example in
Figure 14-3 is the
trigger type
input to the AI Start VI is set to
digital A
(start) trigger. This sets up the waveform acquisition for a digital trigger.
Because the waveform generation uses the same counter/timer as the
waveform acquisition, it also is dependent on the digital trigger.
For a complete description, instructions, and I/O connections for this VI,
select
Windows»Show VI Info…
from the front panel of the VI.