Programming instructions
Chapter 21 Common SCXI Applications
©
National Instruments Corporation 21-17 LabVIEW Data Acquisition Basics Manual
Figure 21-10.
SCXI-1124 Update Channels VI
Digital Input Application Example
To input digital signals through an SCXI chassis, you can use the
SCXI-1162 and SCXI-1162HV modules and the Easy Digital VI,
Read from Digital Port, as shown in Figure 21-11.
Figure 21-11.
Inputting Digital Signals through an SCXI Chassis Using Easy Digital VIs
If you configure channels using the DAQ Channel Wizard,
digital channel
can consist of a digital channel name. The channel name can refer to either
a port or a line in a port. You do not need to specify
device
,
line
, or
port
width
, as theses inputs are not used by LabVIEW if a channel name is
specified in
digital channel
.
As an alternative,
digital channel
can be expressed in the
SCx!MDy!0
format, where you are trying to input from the digital input module on slot
y
of chassis
x
. The last identifier is always port 0, because the whole
module is considered one port. In this example, you must also specify
device
and
port width
. The
port width
should be the number of lines in
a port on your SCXI module if you are operating in multiplexed mode.
For the SCXI-1162 and SCXI-1162HV, the
port width
is 32 lines. If you
are operating in parallel mode, the
port width
should be the number of