User's Manual
Model
Keyboard(UH0G)/Mouse(MH0GC)/Dongle(DHN0)
Form No.: DFE0-01-001-04(030701)
4 12KV B
5 15KV C
Testing Criteria Contact Discharge to EUT
Severity Level Level +/- Acceptance Criteria
1 2KV B
2 4KV B
3 6KV B
4 8KV B
6.2.3 Dongle unit:
Basic standard: EN55024:2010
Generic standard: IEC 61000-4-2:2008
Testing Criteria Air Discharge to EUT
Severity Level Level +/- Acceptance Criteria
1 4KV B
2 8KV B
3 10KV B
4 12KV B
5 15KV C
Testing Criteria Contact Discharge to EUT
Severity Level Level +/- Acceptance Criteria
1 2KV B
2 4KV B
3 6KV B
4 8KV B
6.3 EFT Test
Basic standard: EN55024:2010
Generic standard: IEC61000-4-4: 2012
Performance Criteria: B
Test Voltage: ±2 KV on AC power port for one minute;
±1 KV on signal /control lines .
Temperature: 15~35 ºC
Relative Humidity: 30~60 % RH
9 Green Requirement
Follow as regulation: RoHS, RoHS2