6
39ºC/95%RH
65ºC/20%RH
4
Temperature and Humidity ramp
7
65ºC/20%RH
65ºC/20%RH
24
High temperature & high humidity soak
Hot
8
65ºC/20%RH
25ºC/50%RH
4
Temperature and Humidity ramp
Operational temperature/humidity(package with PE bag)
Test
Step #
Conditions
(from)
Conditions (to)
Operation
Duration
(hours)
Test purpose
Test
Mode
1
25ºC/50% RH
0ºC
Power On,
Function test
2
Temperature and Humidity
ramp
2
0ºC/10% RH
-------
Function test
12
Low temperature function test
Cold
3
0ºC
31ºC/90%RH
Function test
4
Temperature and Humidity
ramp
4
31ºC/90%RH
--------
Function test
12
High humidity test
Damp
5
31ºC/90%RH
40ºC/45%RH
Function test
3
Temperature and Humidity
ramp
6
40ºC/45%RH
--------
Function test
12
High temperature & high
humidity test
Hot
7
40ºC/45%RH
25ºC/50%RH
Function test
2
Temperature and Humidity
ramp
8
Go to step 1
Repeat steps 1-8 for
second cycle
Function test
47
Run 2
nd
loop undocked
Sample shall not show visual crack and deformation after test.
4.2 Environmental Data for reference only
Note: All test-sample to be oven cured 65°C at 24 hours at least prior to carrying out the following
tests to secure the sealing of membrane assembly.
4.2.1 H2S gas test: (reference)
3.0±1 ppm, 28°C, 90%±5% RH Non-Condensing, 200 hours, then reduce RH to 50%±5%RH, keep other
conditions, 50 hours. (250 hours in total)
4.2.2 O3 gas test: (reference)
2.5±0.3 ppm, 28°C, 90%±5% RH Non-Condensing, 200 hours, then reduce RH to 50%±5% RH, 50 hours.
(250 hours in total)
Criterion of 4.2.1 & 4.2.2:
Form No.: A-01-001-09(111107) 保存期限:最新狀態 保存單位:eGRNSystem