Data  Default Zone Configuration 
4 
Entry / Exit Delay 2: Partial – Forced Arming – A trip will start entry delay 2. This zone will be 
active in partial mode. This zone type may be faulted while arming if forced arming is enabled in the 
area options. 
5 
Entry / Exit Delay 2: Partial – Chime – Forced Arming - A trip will start entry delay 2. This zone 
will be active in partial mode. This zone type may be faulted while arming if forced arming is enabled 
in the area options. This zone type will set the code pad chime if set via the code pad [Chime] key. 
6 
Handover: Forced Arming – Interior zone that follows the entry delay zones. Instant alarm type 
unless an entry zone if faulted first. This zone will be bypassed in partial mode. This zone type may 
be faulted while arming if forced arming is enabled in the area options. 
7 
Handover: Partial – Forced Arming – Interior zone that follows the entry delay zones. Instant alarm 
type unless an entry zone if faulted first. This zone will be active in partial mode. This zone type may 
be faulted while arming if forced arming is enabled in the area options. 
8 
Handover: Twin Trip – Forced Arming – Interior zone that follows the entry delay zones. Instant 
alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode. This zone 
type may be faulted while arming if forced arming is enabled in the area options. This zone type will 
require two triggers or another zone would have to have been trigged before it will activate an alarm. 
9 
Handover: Group Isolate – Forced Arming – Interior zone that follows the entry delay zones. 
Instant alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode. 
This zone type may be faulted while arming if forced arming is enabled in the area options. This zone 
type will be part of the group bypass zones. 
10 
Handover: Twin Trip – Chime – Forced Arming – Interior zone that follows the entry delay zones. 
Instant alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode. 
This zone type may be faulted while arming if forced arming is enabled in the area options. This zone 
type will require two triggers or another zone would have to have been trigged before it will activate 
an alarm. This zone type will set the code pad chime if set via the code pad [Chime] key. 
11 
Handover: Partial – Twin Trip – Forced Arming – Interior zone that follows the entry delay zones. 
Instant alarm type unless an entry zone if faulted first. This zone will be active in partial mode. This 
zone type may be faulted while arming if forced arming is enabled in the area options. This zone type 
will require two triggers or another zone would have to have been trigged before it will activate an 
alarm. 
12 
Handover: Partial – Group Bypass – Forced Arming – Interior zone that follows entry delay 
zones. Instant alarm type unless an entry zone if faulted first. This zone will be active in partial mode. 
This zone type may be faulted while arming if forced arming is enabled in the area options. This zone 
type will be part of the group bypass zones. 
13 
Handover: Twin Trip – Group Bypass – Forced Arming – Interior zone that follows the entry delay 
zones. Instant alarm type unless an entry zone if faulted first. This zone will be bypassed in partial 
mode. This zone type may be faulted while arming if forced arming is enabled in the area options. 
This zone type will require two triggers or another zone would have to have been trigged before it will 
activate an alarm. This zone type will be part of the group bypass zones. 
14 
Handover: Partial – Twin Trip – Group Isolate – Forced Arming – Interior zone that follows the 
entry delay zones. Instant alarm type unless an entry zone if faulted first. This zone will be active in 
partial mode. This zone type may be faulted while arming if forced arming is enabled in the area 
options. This zone type will require two triggers or another zone would have to have been trigged 
before it will activate an alarm. This zone type will be part of the group bypass zones. 
15 
Instant: – Produces an instant alarm if tripped when armed. Ignored when disarmed. This zone will 
be bypassed in partial mode. 
16 
Instant: Partial – Produces an instant alarm if tripped when armed. Ignored when disarmed. This 
zone will be active in partial mode. 
17 
Instant: Partial (no DEOL) – Produces an instant alarm if tripped when armed. Ignored when 
disarmed. This zone will be active in partial mode. This zone type will not be enabled for dual end of 
line monitoring if enabled in the system options. 
18 
Instant: Twin Trip – Forced Arming – Produces an instant alarm if tripped when armed. Ignored 
when disarmed. This zone will be bypassed in partial mode. This zone type may be faulted while 
arming if forced arming is enabled in the area options. This zone type will require two triggers or 
another zone would have to have been trigged before it will activate an alarm. 
19 
Instant: Group Bypass – Produces an instant alarm if tripped when armed. Ignored when disarmed. 
This zone will be bypassed in partial mode. This zone type will be part of the group bypass zones. 
20 
Instant: Partial – Chime – Produces an instant alarm if tripped when armed. Ignored when 
disarmed. This zone will be active in partial mode. This zone type will set the code pad chime if set 
via the code pad [Chime] key. 